System identification........................................5 Configuration ............................................6 Configuration modes with Lutron systems ................................6 Configuration with Lutron Palladiom thermostat to control the HVAC zone ..................6 Configuration with Airzone thermostat ................................6 Lutron Configuration ........................................7 Airzone system Configuration ....................................8 System configuration for ACUAZONE / IBPRO32 and FLEXA 3.0 / IBPRO6 .....................
Reading/Writing of the fan speeds. The system requires the connection of at least one Airzone Blueface Thermostat. It allows the control of the conditioning of each zone associated from Lutron Keypads devices, and the control of time schedules both from the HomeWorks QS Processor and from the Lutron Connect App.
SPECIFICATIONS AND ELEMENTS OF THE AIRZONE-LUTRON INTERFACE Ethernet Power supply and consumption Type of power supply Vac Type of cable UTP cat 6 Standard T568B 12 V supplied from V max. the Control Board IP address setting Static I max. 200 mA Mechanical aspects Maximum consumption 1.8 W...
Note: The HomeWorks QS Processor and the Palladiom thermostat must use software version 13.0 or newer. The Airzone-Lutron interface is a Plug&Play device which, when connected to the Airzone Main Control Board and to the HomeWorks QS Processor via Ethernet using the Lutron integration protocol, configures itself and configures the Main Board to work with the Lutron system.
01 for Airzone system 1, 02 for Airzone system 2... Up to 32 Airzone systems. 01 for Airzone zone 1, 02 for Airzone zone 2... Up to 32 Airzone zones per system (based on the type of the system). Example: A Palladiom thermostat DEVICE Integration ID for the Airzone system 1 and for zone 1 will be 20101.
LUTRON CONFIGURATION To perform the integration with the Airzone system in the HomeWorks QS software, please follow the steps below: Define the HVAC zones in the software in the menu design – loads and select HVAC zones. Important: On zoned ducted units the Fan Speed option enabled must be Auto. The “Auto” Operating Mode is only available for Airzone systems in North America.
IDs of the HVAC zones in the format 1XXYY as described on page 6. While still in the Configure Integration screen, select the tab “Telnet Logins”. Add the Username and Passphrase the Airzone-Lutron interface will use to make a Telnet connection with the HomeWorks QS processor. AIRZONE SYSTEM CONFIGURATION System configuration for ACUAZONE / IBPRO32, FLEXA 3.0 / IBPRO6 and RADIANT365...
“airzone” and the pass “lutron” in the access pop-up window. Next, set the Username and Passphrase to match those created in the HWQS software in step 6 as described on page 8. In the Lutron IP Gateway field, enter...
Verify the following items: The D9 LED (Microswitch performance) is blinking. The D7 and D8 LEDs are alternately blinking. The correct connection between the Airzone-Lutron Interface in the Airzone Main Control Board. THE AIRZONE-LUTRON INTERFACE CANNOT BE CONNECTED Verify the following items: LEDs “A”...
Page 11