AM-NX1
• Adjustment Method of ChgI_H
(item number: 758)
LCD display
758
C I H
** : adjusted value
1. In the state of power off, short SL952 on the MAIN board
with a solder bridge. Then, turn on the power.
2. Connect a digital voltmeter to the TP962 (ChgI H) on the MAIN
[VOL +]
board, and adjust
(voltage down) so that the voltage becomes 1.40 ± 0.01V.
MAIN board
TP962 (ChgI H)
TP952 (GND)
3. Press the
key to write the adjusted value.
4. After adjustment, turn off the power and open the solder bridge
on SL952 on the MAIN board.
Adjustment and Connection Location: MAIN board
22
* *
[VOL --]
key (voltage up) or
digital
voltmeter
(see page 22)
Adjustment and Connection Location:
– MAIN Board (Component Side) –
TP902
(VC1)
key
TP913
(REG3)
TP911
(REG1)
TP952
(GND)
– MAIN Board (Conductor Side) –
TP602
(VREC)
TP912 (REG2)
TP905 (VC2)
TP961
TP962
(ChgI_L)
(ChgI_H)
SL952
SL951
TP951
(ChgV)