Toshiba RAV-RM301KRTP Series Service Manual page 89

High wall type
Table of Contents

Advertisement

No.
Part name
5
Fan motor
6
Horizontal louver
Procedures
1) Follow the procedure item 3 and 4 .
2) Loosen the set screw of the cross flow fan.
Cross flow fan
3.5 mm
Set screw
3) Remove 2 fixing screws of the motor band.
4) Pull the motor band and the fan motor
outward.
<To re-installation>
- Check the type name of fan motor.
- Keep connector position and arrange fan
motor wires follow figure.
Fan motor
connector
Fan motor wires
For SJM-240-25
1) Remove shaft of the horizontal louver
from the back body. (First remove 2 the
center shafts then remove the other shafts.)
Body back
Fan motor
Screws
Fan motor wires
For SJM-240-35
- 89 -
FILE NO. SVM-18059
Remarks
Cross flow fan
Vertical louver
Hexagon screw driver
Fan motor
Fan motor
connector
Drain pan
Horizontal louver
Motor band

Hide quick links:

Advertisement

Table of Contents
loading