Code No - Toshiba RAV-RM301KRTP Series Service Manual

High wall type
Table of Contents

Advertisement

CODE No. (DN) table (Please record the objective unit data at field)
DN
Item
01
Filter sign lighting time
02
Dirty state of filter
03
Central control address
06
Heating suction temp shift
0C
PRE-DEF indication selection
0d
Cooling auto mode existence
0F
Cooling only
10
Type
11
Indoor unit capacity (See below table)
12
Refrigerant line address
13
Indoor unit address
14
Group address
1E
Temp difference of automatic cooling/
heating selecting control points
28
Auto restart
2A
Option input selection (CN80)
2b
Thermo output selection (T10
2E
Input selection (T10
32
Sensor selection
Dual Set Point
77
B3
Soft Cooling
Indoor unit capacity (CODE No. [11])
SET DATA
0000*
0003
0006
0009
0012
∗ Initial value of EEPROM installed on the supplied service P .C. board
Be sure to set as 0008
ƒ
)

)
Model
Invalid
30
40
56
80
Memo
0001: 150 hour
0000: Standard
0099: Unfixed
0002: +2°C
0000: Standard
0000: Auto mode
cooling/heating
0000: Heat pump
0008: High wall type
According to capacity type
0099: Unfixed
0099: Unfixed
0099: Unfixed
0003: 3deg (Ts ± 1.5)
0000: None
0002: External emergency input
0000: Thermo ON
0000: Operation input
0000: Body sensor
0000: Unavailable
0001: Available
- 65 -
FILE NO. SVM-18059
At shipment
Automatic selection by
connected outdoor unit