Outdoor Unit : RAS-3M18U2AVG-E, -TR
< Heating >
Temperature
No. of
Condition
operating
Indoor
Outdoor
units
1 unit
2 Units
27/19
35/-
3 Units
NOTES:
1.Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent.(Thermistor thermometer)
2.Connecting piping condition : 5 meters × 2 units(5m/each indoor unit)
Standard
Indoor unit
pressure
A
B
C
P (MPa)
05
-
-
2.2
07
-
-
2.2
10
-
-
2.9
13
-
-
3.3
16
-
-
3.2
05
05
-
2.9
07
05
-
2.9
10
05
-
3.0
13
05
2.9
16
05
2.6
07
07
-
2.5
10
07
-
2.9
13
07
2.8
16
07
2.5
10
10
2.8
13
10
2.7
16
10
2.4
13
13
-
2.6
16
13
2.3
16
16
-
2.1
05
05
05
2.2
07
05
05
2.3
10
05
05
2.2
13
05
05
2.1
16
05
05
2.0
07
07
07
2.1
10
07
07
2.1
13
07
07
2.0
16
07
07
1.9
10
10
07
2.0
13
10
07
2.0
16
10
07
1.9
13
13
07
1.9
16
13
07
1.9
10
10
10
2.0
13
10
10
2.0
16
10
10
1.9
13
13
10
1.9
Heat exchanger
pipe temperature
o
T1 (
C)
to
2.4
39
to
41
to
2.4
39
to
41
to
3.1
48
to
50
to
3.5
52
to
54
to
3.4
51
to
53
to
3.1
40
to
42
to
3.1
46
to
48
to
3.2
46
to
48
to
3.1
44
to
46
to
2.8
41
to
43
to
2.7
41
to
43
to
3.1
47
to
49
to
3.0
45
to
47
to
2.7
42
to
44
to
3.0
46
to
48
to
2.9
44
to
46
to
2.6
41
to
43
to
2.8
43
to
45
to
2.5
39
to
41
to
2.3
37
to
39
to
2.4
37
to
39
to
2.5
36
to
38
to
2.4
36
to
38
to
2.3
36
to
38
to
2.2
34
to
36
to
2.3
36
to
38
to
2.3
35
to
37
to
2.2
35
to
37
to
2.1
33
to
35
to
2.2
35
to
37
to
2.2
34
to
36
to
2.1
33
to
35
to
2.1
33
to
35
to
2.1
32
to
34
to
2.2
34
to
36
to
2.2
34
to
36
to
2.1
32
to
34
to
2.1
33
to
35
- 52 -
FILE NO. SVM-18020-2
Indoor fan
o
T2 (
C)
3
to
5
High
3
to
5
High
2
to
4
High
1
to
3
High
1
to
3
High
3
to
5
High
3
to
5
High
2
to
4
High
1
to
3
High
1
to
3
High
0
to
2
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
-1
to
1
High
Compressor
revolution
(rps)
33
37
55
67
73
35
37
55
67
73
71
90
91
91
91
91
91
91
90
90
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93

Hide quick links: