Toshiba RAS-2M14U2AVG-E Service Manual page 113

Hide thumbs Also See for RAS-2M14U2AVG-E:
Table of Contents

Advertisement

No. Part name
1. Detachment
Electronic
expansion
1) Perform step 1 in 2 , all the steps in 3 and
valve coil
2) Turn the coil by 180 degrees then remove
Attachment
2.
1) Insert the coil at position which
perpendicular with pipe of PMV then turn
the coil by 180 degrees.
⑨ Fan guard
1.Detachment
1) Perform works ① and ②.
2) Remove the front cabinet, and put it down so
that fan guard side directs downward.
3) Remove the hooking claws by pushing minus
screwdriver according to the arrow mark in the
right figure, and remove the fan guard.
2. Attachment
1) Insert claws of the fan guard in the holes of the
front cabinet. Push the hooking claws
(9 positions) by hands and fix the claws.
All the attaching works have completed. 
Check that all the hooking claws are fixed to
the specified positions.
<Handling precaution>
When handling the parts, do not pull the leads.
When removing the coil from the valve body, use
your hand to secure the body in order to prevent
the pipe from being bent out of shape.
Procedure
1 in 4 .
by pull it upward.
Make sure that lead wire of coil
is opposite with pipe of PMV
Perform work on a corrugated cardboard,
cloth, etc. to prevent flaw to the product.
Rotate 180°C
- 113 -
FILE NO. SVM-18020
Remarks
BODY-PMV
COIL-PMV

Hide quick links:

Advertisement

Table of Contents
loading