Toshiba RAS-2M14U2AVG-E Service Manual page 110

Hide thumbs Also See for RAS-2M14U2AVG-E:
Table of Contents

Advertisement

No. Part name
③ Inverter
10) Disconnect the leads connected to the other
assembly
parts from the P.C. assembly.
(continued)
These connectors have the lock. The lock must
be released before they are disconnected.
Main P.C. board
CN300 : Outdoor fan motor (3P : white)
CN500 : Thermostat for compressor (2P : blue)
CN501 : High pressure switch (3P : green)
CN704 : 4 way valve coil (2P : white)
Control P.C. board
CN01 : AC-IN (2P : Red)
CN02 : Sirial connunication (3P : Black)
CN600 : TD sensor (3P : white)
CN601 : TE sensor (2P : white)
CN602 : TO sensor (2P : white)
CN603 : TS sensor (3P : white)
CN604 : TGa sensor (2P : yellow)
CN605 : TGb sensor (2P : red)
CN606 : TGc sensor (2P : green)
CN700 : PMV A (6P : yellow)
CN701 : PMV B (6P : red)
CN702 : PMV C (6P : green)
CN805 : Display P.C. board (10P : white)
Connected connector of main and control
CN806 and CN802 (5P : blue)
11) Remove the heatsink.
(ST2TØ3×12L 5pcs.)
12) Remove the PCB base.
When mounting the new control board assembly,
ensure that the P.C. board is inserted properly into
the P.C. board support groove.
Procedure
*only 3M18 and 2M18
*only 3M series
*only 3M series
- 110 -
FILE NO. SVM-18020
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents