Printed Circuit Board Connector Wiring Diagram - GE GES-NX2G70OUT Service Manual

Wall mounted type dc inverter
Table of Contents

Advertisement

6. Printed circuit board connector wiring diagram

Connectors
PCB (1) (Control PCB) For GES-NX2G70OUT
1) CN1, CN2 Connector for power N and L
2) CN3 Connector for ground
3) CN23 Connector for DC POWER 15Vand 5V to the module board
4) CN10, CN9 Connector for CN8,CN9 on the module board
5) CN22 Connector for fan motor
6) CN15 Connector for four way valve coil
7) CN17,CN18,CN19,CN47
8) CN24 Connector for communicate between the control board and the module board
9) CN28, CN25 Connector to P and N of the module board
10) CN36 Connector for communicate between indoor and outdoor unit
PCB (2) (Module PCB) For GES-NX2G70OUT
CN10 Connector for the DC power 5V and 15V form the control PCB
CN11 Connector for communicate between the control board and the module board
P (CN8), N (CN9) Connector for capacitance board
LI (CN3), LO (CN4) Connector for reactor
CN5, CN6, CN7 Connector for the U, V, W wire of the
Notes: Other Designations
PCB (1) (Control PCB)
1) FUSE 1, (25A, 250VAC); FUSE 2(1A, 250VAC)
2) LED 1 Keep light representative normal, if keep flash interval representative trouble Alarm
3) RV1, RV2, RV3 Varistor
Printed circuit board connector wiring diagram
Connector for thermistors
11