To reduce the risk of fire and explosion, always
maintain a minimum of 1 in. clearance inside the
material drum between rotating agitator parts and
any other objects, including the drum to prevent
sparks from contact. This includes the edges of the
drum as well as any item which may be inserted
into the drum from another opening, such as feed
pumps or suction tubes.
With
With
With an
an Elevator
an
Elevator
Elevator
To reduce the risk of injury from being crushed
by equipment, do not go under the elevator when
it is raised.
Mount the drum cover as described in the Elevators
and Pump Supports Manual 306287. The elevator
must be in the down position when you do any work
on the elevator, agitator, or drum cover assembly.
3A4032B
Positioning the
the
Positioning
the
Without an
Without
Without
an Elevator
an
Elevator
Elevator
When included in a package without an elevator, the
drum cover is provided with handles for easy lifting
and positioning. For additional handles, order the
Handles Kit, part 237524.
Place two standard 55 U.S. gallon (45 Imperial
gallon, 200 L) drums 14 in. (36 cm) apart, and center
the drum cover on the barrels.
1. Install the four lock nuts (A2) holding the agitator
to the drum cover.
2. Tighten the lock nuts to 30 ft-lb (40.6 N•m).
Installation