Download Print this page

VGE Blue Lagoon Saltwater UV-C Manual page 7

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
INSTALLATION OF THE EARTH (DRAWING 1)
1. Pull the cable (2) through the strain relief (4) before fitting the synthetic strain relief (4) onto the earth
bolt (1). Position the strain relief (4) at approximately 10 cm from the eye (2) of the earth cable.
2. Place the eye (2) of the cable onto the earth bolt that is fitted to the housing.
3. Then place a toothed lock washer (3).
4. Fit the strain relief (4), creating a loop of Ø5 cm.
5. Finally place the second toothed lock washer (5) and the lock nut (6) onto the earth bolt.
6. Once the parts have been placed onto the earth bolt in the correct sequence, they can be tightened
with a spanner or a ring spanner number 8.
INSTALLATION OF THE DEVICE (DRAWING 2)
Determine where the device will be installed. The Blue Lagoon Saltwater UV-C must never be installed
behind the Ph regulator, the heater or the salt electrolysis system in your swimming pool installation.
The ideal location to install your device is immediately behind the filter. The installation must always take
place outside of the pool. Ensure that there is always water flowing through the unit when the lamp is
on. Never install the unit in an area exposed to full sunlight. The installation must always take place in a
dry and well-ventilated area.
1. Determine where the device will be installed. Make sure to leave a free area (+/- 1 metre) in order to be
able to remove the lamp (K) /quartz glass (M) for the purpose of replacement and/or maintenance.
2. Fit the supplied pipe clips (O) in fixed positions, press the unit into the pipe clips and tighten the three-
part coupling (I). Pay hereby attention to the correct position of the sealing rings (P), both with regard to
the connections and the quartz glass.
3. Fit the unit into the circuit using the three-part couplings (I). The inlet and outlet of the three-part
coupling is Ø 63 mm. If your pipes are smaller than 63 mm, you can use the adapter (Ø 63 x Ø 50 mm)
(T). This must be glued onto the three-part coupling (I). On one side of the adapter (T), there is a screw
thread on the inside giving the option of fitting an adapter, with a sealing ring (not included in the
delivery), onto it if necessary. Adapter sets can be obtained from your distributor.
4. Unscrew the screw ring (N) from the housing (U). Remove the UV-C lamp (K) from the supplied case
(see packaging) and carefully slide the lamp into the quartz glass (M). Carefully connect the lamp holder
(L) to the UV-C lamp (K) and then screw the screw ring (N) hand-tight onto the housing (U).
5. Activate the pump and check the flow and any leakage of the system.
6. Put the plug of the UV-C device in a wall socket with a safety ground and fitted with a residual current
circuit-breaker. Check whether the lamp is operating by looking through the transparent components
of the unit. The unit is switched off by pulling the plug out of the socket.
DISMANTLING / MAINTENANCE
Always switch off the power supply during maintenance/dismantling of the device. The device must be
cleaned at least twice a year. If there is an increase in algae and/or scale, the quartz glass tube (M) in which
the lamp is positioned must be cleaned. The special lamp must be replaced once a year. The PVC interior
can be cleaned with a soft brush. The lamp must be replaced after 9.000 operating hours.
UV-C and Pool equipment
BLUE LAGOON SALTWATER UV-C |
EN
7

Advertisement

loading

This manual is also suitable for:

Blue lagoon saltwater uv-c 40.000Blue lagoon saltwater short uv-c 40.000Blue lagoon saltwater uv-c 75.000Be06402Be07402Be06752