2. Insert flat blade screwdriver to release hinge pin from left hinge.
3. Slide out left hinge pin to release the door.
4. Slide out door arms from the oven to disconnect door assembly.
5. Remove door arms from the door assembly.
To remove door C
6. Release catch hooks.
NOTE:
After replacement of the defective component parts of the door, reassemble it and follow the instruction below for
proper installation and adjustment so as to prevent an excessive microwave leakage. Adjustment of the door
assembly.
7. When mounting the door to the oven, be sure to adjust the door parallel to the cavity front plate by moving hinges back
or front.
NOTE:
Upper portion of door A should firmly touch the cavity front plate without pushing.
4.9 Pump
1. Draw out water tank from escutcheon base.
2. Pull out tube A connecting to pump from copper pipe.
3. Remove all wiring connectors from D.P.C board AU.
4. Remove 1 grounding screw holding on cavity front plate.
5. Open the door of oven, slide the escutcheon base upward and out slightly.
6. Pull out tube B from inlet of pump.
7. Remove 2 screws holding pump bracket on escutcheon base.