2.6 Bearing Status Check

Fix the sensor directly to the bearing housing as close to the bearing as possible. Note
that valid high frequency readings are unlikely to be measured using hand-pressure and
the spike.
Press the BRG key to enter the Bearing Status mode.
Press the SEL key to select either Bg (g RMS) or Bv (mm/s RMS).
When the bearing status reading has settled, press the BRG key to enter the Hold Mode
(H). The bearing status reading is then held and the rule-of-thumb alarm status displayed.
Press the SEL key to toggle through and select the appropriate speed range of the
bearing shaft. (rpm: <500, rpm: <1000, rpm: <2000, rpm: <5000, rpm:<10000).
The meter will then indicate either a tick icon for OK, a single bell for vibration alert or
two bells for danger.
The meter makes the assessment based on the rules-of-thumb defined in section 4.
2.7 Battery & Charger
The vibration Meter is powered by an internal rechargeable Lithium-Ion battery which can
operate for 48 hours continuously following full charge. The battery condition is indicated
by an icon at the top right of the meter display.
The battery charger supplied requires 3 hours to fully charge the battery. An LED on
the charger indicated the charge status, being orange when charging and green when
charging is complete.