Bv Value; Temperature Mode (Hs-630 Only) - Hansford sensors HS-620 User Manual

Hide thumbs Also See for HS-620:
Table of Contents

Advertisement

4.2 BV Values
BV measurement is a long established method for detecting bearing faults which gives
reliable indication of bearing condition in 80-90% of cases. The rule-of-thumb assessment
used in the metre is as follows:
• BV < 1mm/s
• BV = 1-2mm/s -
• BV > 2mm/s

5. Temperature Mode (HS-630 only)

The HS-630 uses a thermopile infra-red sensor to indicate temperature in Deg. C or Deg.
F on the display. An alignment laser beam is provided to indicate the area where the
temperature is being measured. Ambient temperature is also indicated in the bottom left
of the display.
BNC connector
LCD Screen
VIB Key
BRG Key
Caution - Laser radiation - Do not stare into the Laser beam
QM014 Issue 5
-
Healthy bearing, correctly greased
Possibly damaged or un-greased bearing
-
Bearing seizure likely
TEMP Key
SEL Key
Laser Beam
Figure 4. HS-630
- 11 -
HS-620/630 User Guide
Integral Cable
Hand Probe
with Sensor