6. Specifications
Input:
Vibration:
Bearing:
Temp. Range:
Laser Guide:
Distance Range:
Accuracy:
Display:
Power:
Temperature:
Meter Sealing:
Spike Length:
Magnetic Base:
Meter Size:
Carry Case Size:
Weight:
Cable Length:
QM014 Issue 5
Constant Current Accelerometer 100mV/g other inputs on request
Acceleration: 0-50gPk, Frequency Range 10Hz-12kHz
Velocity:0-350 mm/s RMS, Freq. Range 10Hz-1kHz
Automatic Alarm Check: ISO10816-3.
Displacement: 0-4000µm Peak-Peak,
Freq. Range 10Hz-1kHz
Bg: 0-20 g RMS Freq. Range 1kHz -12 kHz Applies to
Bg line & Bv line.
Bv: 0-25 mm/s RMS, Freq. Range 1kHz-12 kHz
Automatic Alarm Check for BG and BV: Rule-of-thumb
-40°C to 150°C or -40°F to +300°F (HS-630 only)
Red, λ=650nm <1mW, IEC 60825-1 compliant (HS-630 only)
For Temp. measurement 0 to 2 metres (HS-630)
+/-5%
LCD
Lithium rechargeable battery, 3.6V 1700 mAh,
Recharge time 3 hours, >48 hours continuous operation
Operation: -10°C to +50°C; Storage: -20°C to +60°C
IP64 – Dust tight and splash resistant
75mm
Diameter 25mm, H 17mm, pull strength 12Kg
L 115mm x W 70mm x D 25mm
W 342mm x D 265mm x H 80mm
Full kit including carry case 1.25 Kgs
0.8m (other lengths available)
- 13 -
HS-620/630 User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hs-630