Download Print this page

Ricoh Skylark A183 Technical Bulletin page 3

Hide thumbs Also See for Skylark A183:

Advertisement

RICOH
Model:
Skylark
Subject:
SC Code #96
From:
QAC 1st Field Information Dept.
Classification:
The following should be added to the "SERVICE CALL CONDITIONS" in the Service
Manual.
CODE #96 - MAIN SWITCH ERROR
Definition
The machine does not turn off within 8.5 seconds after Auto Shut Off is performed.
Possible Causes
• Defective main switch.
• Connectors of the main switch are not correctly connected.
• Defective dc harness of the main switch connection (some lines must be cut.)
∗Remedy for the initially produced machines
• Turn the main switch off and on.
T
echnical
Troubleshooting
Mechanical
Paper path
Other (
)
B
ulletin
Date:
31-Mar-97
Prepared by:
Checked by:
Part information
Electrical
Transmit/receive
PAGE: 1/1
No:
2
M.Ishihara
T. Inoue
Action required
Service manual revision
Retrofit information

Advertisement

loading

This manual is also suitable for:

Skylark a184Rtb-001