Download Print this page

Ricoh Skylark A183 Technical Bulletin page 12

Hide thumbs Also See for Skylark A183:

Advertisement

RICOH
Model:
Skylark
Subject:
Remaining top of toner bottle
From:
QAC 1st Field Information Dept.
Classification:
When replacing an empty toner bottle with a new one, the top [ A ] of the toner bottle may
remain in the IU (Imaging Unit) due to procedural error such as removing the empty bottle
from the IU without lifting up the lever [ B ].
The following procedure is required when the top of the toner bottle remains in the IU.
1) Lift up the lever [ B ] of the IU.
2) Pick the top [ A ] of the toner bottle out from the IU.
T
echnical
Troubleshooting
Mechanical
Paper path
Other (
)
B
B
ulletin
Date:
15-May-97
Prepared by:
Part information
Electrical
Transmit/receive
IU
A
PAGE: 1/1
No:
6
M.Ishihara
Action required
Service manual revision
Retrofit information

Advertisement

loading

This manual is also suitable for:

Skylark a184Rtb-001