Touchscreen

Calibrating the Touchscreen

If the touchscreen is not responding properly to stylus taps,
you may need to recalibrate the touchscreen.
Recalibration involves tapping the center of a target. If you
miss the center, keep the stylus on the screen, slide it over
the target's center, and then lift the stylus.
Follow the instructions on the screen and press the Enter key
to save the new calibration settings or press Esc to cancel or
quit.

Adjusting the Display Backlight Timer

The backlight settings use the LXE set of default timeouts
and are synchronized to the User Idle setting in the Schemes
tab in the Power control panel.
When the backlight timer expires, the display backlight is
dimmed, not turned off. When both checkboxes are
unchecked, the backlight never turns off (or dims).
Default values are 3 seconds for Battery, 2 minutes for
External and both the check boxes are enabled.

Setup Terminal Emulation Parameters

Before you make a host connection, you will, at a minimum,
need to know:
the alias name or IP address (Host Address) and
l
the port number (Telnet Port) of the host system to
l
properly set up your host session.
1. Make sure the mobile client network settings are con-
figured and functional. If you are connecting over wire-
less LAN (802.11x), make sure your mobile client is
communicating with the Access Point.
2. From Start | Program, run LXE RFTerm or tap the
RFTerm icon on the desktop.
3. Select Session | Configure from the application
menu and select the "host type" that you require. This
will depend on the type of host system that you are
going to connect to; i.e. 3270 mainframe, AS/400
5250 server or VT host.
4. Enter the "Host Address" of the host system that you
wish to connect to. This may either be a DNS name
or an IP address of the host system.
5. Update the telnet port number, if your host appli-
cation is configured to listen on a specific port. If not,
just use the default telnet port.
6. Select OK.
E-EQ-THORCEOGWW-A [ 17  ] Thor CE User Guide
7. Select Session | Connect from the application menu
or tap the "Connect" button on the Tool Bar. Upon a
successful connection, you should see the host appli-
cation screen displayed.
To change options such as Display, Colors, Cursor,
Barcode, etc., please refer to these sections in the RFTerm
Reference Guide for complete descriptions of these and
other features.