SECO-LARM E-946FC-600Q Manual page 6

Electromagnetic gate locks with face or surface mounting
Table of Contents

Advertisement

SECO-LARM Electromagnetic Gate Locks with Face or Surface Mounting
Installation,
continued
2. Mount the electromagnet. In most cases, the position of the electromagnet will determine the
location of the armature plate. Make sure there is space to run the cable.
a. Tape the template to the
appropriate location.
b. Drill four (E-946FC-1K2Q) or two
(E-946FC-600Q) 9.5mm (
holes, one for each short hex
screw. IMPORTANT: The holes
must be 9.5mm (
larger.
c. Insert a blind nut in one of the
9.5mm (
d. Put the washer on the M6x30
screw. Then put the hex tool on the
screw. Then turn the screw by
hand into the blind nut.
e. Use a wrench or vice-grip to tightly
hold the hex tool. Then use the
included Allen wrench to slowly
tighten the screw until it does not
turn any further. This compresses
the blind nut so that it remains
permanently fixed in the hole.
f. Remove the screw.
g. Repeat steps c through f for the
other blind nuts.
h. Push hex screws into each of the
screw holes in the electromagnet.
Use the Allen wrench to tighten the
screws into the blind nuts.
Hold with wrench or vice
grip while turning hex screw
6
:
/
3
8
/
"). No smaller or
3
8
/
") holes.
3
8
Washer
Blind nut
")
Surface mounting
(E-946FC-600Q shown)
Face mounting
(E-946FC-600Q shown)
Hex screw (M6x30 thread)
Hex tool
Door header
SECO-LARM U.S.A., Inc.
.
Allen wrench

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-946fc-1k2q

Table of Contents