• Using (2) AA batteries connected in SERIES, connect the
Positive end to the connector specified each PWB.
• Connect the GROUND end to the ground location specified.
• The AA batteries will provide a 3VDC to the Main Power Relay
and other circuits necessary to turn on the Power Supply.
• Test all output voltages of the Supply.
• If the supply does not activate, ensure the 3V source is connected
properly, then troubleshoot the Switching Circuits.
•Any external Power Supply may be used to provide the 3VDC
turn on voltage.

Advertisement