TELEVISION
AC In
5
OVP
GND
TSD
4
VCC
OSC
S
DRV
3
D
2
ST R-
1
F6514/5
Ocp/
FB
SWITCH CIRCUIT REVIEW
POWER ON
Relay
REG
Refresh
1STB13
Power ON command
B1
received by Micon
Micon turns off Photo
Coupler and turns on Main
Power Relay and circuits
Error Amp monitors B1
1STB13
and controls Switching IC
off time.
5V
Refresh Circuit added in
case TV circuits require
additional power.
CPU
Refresh circuit allows
Switching IC to be turned
On whenever needed by
applying 2V pulse to IC.