Safety Devices - Rheem Classic Plus Series Manual

Side discharge heat pump
Table of Contents

Advertisement

Safety Devices

Air
RP17**H Series
Safety Devices
Type of Protection
Circuit protection
Fan motor protection
Compressor protection
High pressure protection
Type of Protection
Fuse (Filter PCB)
Protector (Filter PCB)
Fuse (MAIN PCB)
Fuse (INV PCB)
Fan motor protection
Compressor protector
High pressure protection
28
Protection From
Current fuse (filter PCB)
Current fuse (main PCB)
Thermal protection
Thermal protection program
(Compressor temp.)
Thermal protection program
(Discharge temp.) (Cool or Dry mode)
Thermal protection program (Outdoor temp.)
Pressure switch
Protection From
Thermal protection
Over current protection
Temperature protection
Thermal protection program (Discharge temp.)
RP1724HJVXA
250 V, 5 A x 2
250 V, 3.15 A x 2
+ 27 -18
302
Activate
Fan motor stop
+ 27 -18
248
Reset
Fan motor restart
226°F (108°C)
Activate
Compressor stop
176°F (80°C)
Reset
Compressor restart
230°F (110°C)
Activate
Compressor stop
After 7 minutes
Reset
Compressor restart
Activate
Reset
4.2 ± 0.1 MPa
Activate
Compressor stop
3.2 ± 0.15 MPa
Reset
Compressor restart
RP1736HJVXA
AC 250 V, 5 A
AC 250 V, 10 A x 2
AC 500 V, 45 A
AC 250 V, 3.15 A x 2
AC/DC 400 V, 5 A
239 ± 27°F (115 ± 15°C)
Activate
Fan motor stop
158°F (70°C)
Reset
Fan motor restart
226.4°F (108°C)
Activate
Compressor stop
176°F (80°C)
Reset
Compressor restart
230°F (110°C)
Activate
Compressor stop
After 3 minutes and 230°F (110°C) less than
Reset
Compressor restart
Activate
580 psi (4.0 MPa)
Reset
471 psi (3.25 MPa)
Model
RP1730HJVXA
+ 15 -10
°F (150
°C)
+ 15 -10
°F (120
°C)
Model
RP1748HJVXA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents