12.AUTO CALIBRATION

12.5 AGC

This procedure is for Rx calibration.
In this procedure, We can get RSSI correction value. Set band EGSM and press Start button the
result window will show correction values per every power level and gain code and the same
measure is performed per every frequency.

12.6 APC

This procedure is for Tx calibration.
In this procedure you can get proper scale factor value and measured power level.

12.7 ADC

This procedure is for battery calibration.
You can get main Battery Config Table and temperature Config Table will be reset.

12.8 Target Power

BAND
GSM 850
EGSM 900
DCS1800
PCS 1900
LGE Internal Use Only
Description
Low
Channel
Frequency
824.2 MHz
Max power
32.5 dBm
Channel
Frequency
880.2 MHz
Max power
32.5 dBm
Channel
Frequency
1710.2 MHz
Max power
29.5 dBm
Channel
Frequency
1850.2 MHz
Max power
29.5 dBm
- 146 -
11. AUTO CALIBRATION
Middle
128
191
836.8 MHz
32.5 dBm
975
37
897.4 MHz
32.5 dBm
512
699
1747.6 MHz
29.5 dBm
512
661
1880 MHz
29.5 dBm
134/140
Copyright © 2011 LG Electronics. Inc. All right reserved.
High
251
848.8 MHz
32.5 dBm
124
914.8 MHz
32.5 dBm
885
1784.8 MHz
29.5 dBm
810
1909.8 MHz
29.5 dBm
Only for training and service purposes