12.6 AGC
This procedure is for Rx calibration.
In this procedure, We can get RSSI correction value. Set band EGSM and press Start button the
result window will show correction values per every power level and gain code and the same
measure is performed per every frequency.
12.7 APC
This procedure is for Tx calibration.
In this procedure you can get proper scale factor value and measured power level.
12.8 ADC
This procedure is for battery calibration.
You can get main Battery Config Table and temperature Config Table will be reset.
12.9 Target Power
BAND
Description
Channel
GSM 850
Frequency
Max power
Channel
EGSM 900
Frequency
Max power
Channel
DCS1800
Frequency
Max power
Channel
PCS 1900
Frequency
Max power
LGE Internal Use Only
Low
Middle
128
191
824.2 MHz
836.8 MHz
32.5 dBm
32.5 dBm
975
37
880.2 MHz
897.4 MHz
32.5 dBm
32.5 dBm
512
699
1710.2 MHz
1747.6 MHz
29.5 dBm
29.5 dBm
512
661
1850.2 MHz
1880 MHz
30 dBm
30 dBm
- 159 -
12. AUTO CALIBRATION
High
251
848.8 MHz
32.5 dBm
124
914.8 MHz
32.5 dBm
885
1784.8 MHz
29.5 dBm
810
1909.8 MHz
30 dBm
Copyright © 011 LG Electronics. Inc. All right reserved.