Section 4: Technical Data - Zenith HydroTap G5 Quick Start Installation Manual

Command centre chilled, chilled/sparkling models
Hide thumbs Also See for HydroTap G5:
Table of Contents

Advertisement

Technical data
Model
CS100
C100
C40
CS Home
C Home
including vent tray
#
Electricity supply requirements
220-240V 50Hz AC (for power requirement see table above).
Required
1x 220 - 240V AC 10A socket
Water supply pressure requirements
Component
HydroTap
Sparkling HydroTap
A pressure limiting valve must be fitted for mains water pressures
!
above the maximum limits stated above in accordance with local
plumbing regulations. Note: All models (excluding UK) have an
internal pressure limiting device to reduce the maximum mains regulated
pressure (700kPa in NZ/Australia), protecting the system against pressure
surges above 500kPa.
Water supply connection
1/2" BSP (G1/2).
Quick Start Installation Guide
8
807120NZ v1.00 01.21 G5 C CS Quick Start Guide

SECTION 4: Technical data

Power rating
kW
0.37
0.34
0.16
0.18
0.17
Min - Max pressure, kPA (bar)
170 (1.7) - 700 (7.0)
250 (2.5 ) - 700 (7.0)
Dimensions
W x D x H (mm)
330 (500)
x 477 x 333
#
330 (500)
x 470 x 333
#
330 x 470 x 333
280 x 406 x 333
280 x 406 x 333
NZ/Australia
Weight
(kg)
36.5
24.2
24.2
30
21

Advertisement