Section 3: Warnings And Regulatory Information - Zenith HydroTap G5 Quick Start Installation Manual

Command centre chilled, chilled/sparkling models
Hide thumbs Also See for HydroTap G5:
Table of Contents

Advertisement

SECTION 3: WARNINGS & REGULATORY INFORMATION
!
• All installation and service work must be completed by
trained and suitably qualified tradespeople. Faulty operation due
to unqualified persons working on this product, may void warranty
coverage.
• As the installer, it is your responsibility to supply (if necessary) and
install all valves as required by local regulations and relevant standards.
• The HydroTap is rated for 220-240V 50Hz AC operation.
• Do not remove the cover of the appliance under any circumstances
without first isolating the appliance from the power supply.
• Connect only to a potable (wholesome cat1) mains water supply.
• Never locate the system near, or clean with water jets.
• Do not expose the Zenith HydroTap to the elements of nature.
• Use of tools can be hazardous. Assess the risks before you start.
• A pressure limiting valve must be fitted for mains water pressures above
the maximum limits stated.
• A clearance envelope around all Command Centres must be provided to
allow adequate ventilation for the safe and effective use of the HydroTap
system.
• The vent tray, if provided, must be fitted. It provides a safe exhaust for
refrigerant gas in the unlikely event of a leak.
• Valves and fittings must be sealed appropriately with PTFE tape.
• Always flush new filter before use.
Quick Start Installation Guide
6
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
The Zenith HydroTap must be earthed, earthing
is provided via the supplied power cord. The resistance of
the earth connection to each exposed metal part must be
less than 1Ω.
Use the power cable supplied. It is the responsibility of the
!
installer to ensure the power point is earthed.

Advertisement

Table of Contents
loading

Table of Contents