APPLICATION
This model series contains the starter plenum, its primary application is Econar manufactured
water source heat pumps. However, it can easily be adapted to other manufacturers
(ClimateMaster, etc.) having a 16 x 16 starting collar.
Electro Industries also has insert models (without starter plenum) primarily intended for
Command-Aire or other water source heat pump brands. Contact factory for assistance.
For information, all units are rated at 24Ø volts AC. When operating at lower source voltage,
the output may be reduced.
Example:
NOTE: The maximum inlet air temperature is 100° F. For inlet temperatures greater than
100°, contact the factory for special assistance.
NOTICE TO HOMEOWNER AND INSTALLER
Hi-limit cycling two to ten minutes after initial turn on usually means improper deflector, baffle
installation, or insufficient airflow - carefully study and follow mechanical installations.
1. All installation work must be performed by trained, qualified contractors or technicians.
Electro Industries, Inc., sponsors installation and service schools to assist the installer.
2. All electrical wiring must be in accordance with National Electric Code and local electric
codes, ordinances, and regulations.
3. Observe electric polarity and wiring colors. Failure to observe could cause electric shock
and/or damage to the equipment.
4. This unit can only be used for its intended design as described in this manual. Any internal
wiring changes, modifications to the circuit board, modifications or bypass of any controls, or
installation practices not according to the details of this manual will void the product
warranty, the ARL certification label, and manufacturer product liability. Electro Industries,
Inc., cannot be held responsible for field modifications, incorrect installation, and conditions
which may bypass or compromise the built-in safety features and controls.
12/20/2017
9.6KW unit, assuming normal element tolerances
220 volt source - 8KW
208 volt source - 7.3KW

INSTALLATION REQUIREMENTS