Page 1
Control Panels, Button Panels and Pre-wired Systems for Elevators Rev.03 Via San Carlo 13 - 20010 Bareggio - Milan - ITALY 20/07/09 Tel: +39 02 90 36 34 99 - Fax: +39 02 90 36 35 00 Internet: www.seasystems.it - e-mail: sea@seasystems.it...
Page 2
LED signals on the STK3-B board. Warning As our products are continuously evolving, the SEA SYSTEMS reserves the right to alter the information contained in this manual without prior notice. Support documentation will be supplied for the additional or modified functions of customized products.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators INDEX FUNCTIONAL FEATURES................ 4 INSTALLATION..................5 2.1. G ........................6 ENERAL OTES 2.2. S ........................7 AFETY EASURES 2.3. T ..........................7 ERMS 2.4. P ......................8...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators FUNCTIONAL FEATURES TYPE OF ELEVATORS CABLE - HYDRAULIC DIRECT, STAR-DELTA, SOFT STARTER, SOFT STOP, ELECTRONIC VALVE OPERATIONS - SIMPLEX UNIVERSAL - SIMPLEX GROUP DESCENT...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators INSTALLATION Fig. 2.1 - General pre-wiring layout with paragraphs for reference during installation SHAFT: Par. 2.7 CAB ROOF: Par. 2.8 CONTROL PANEL: Par.
• The terms of warrantee are indicated on the back of the product transport documents. This warrantee provides the security that SEA SYSTEMS will support its products should defects manifest within the established period. The warrantee is null if the product is used incorrectly or is modified to alter its performance beyond the original factory specifications.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.2. S AFETY EASURES • The installation of the equipment must be performed by a qualified technician, who under his/her own responsibility guarantees following the standards for good workmanship.
• Check the status of all components and materials upon receipt on site in order to identify any possible damages due to transport. Immediately notify SEA SYSTEMS S.r.l. is there are any missing or damaged parts.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.5. F ASTENING ONTROL PANEL Mounting the panel in a traditional Machine Room Fasten the two supports to the upper and lower parts of the control panel.
Page 10
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Mounting the panel on MRL systems guides Fasten the two supports on the upper and lower parts of the control panel. Fasten the support plates to the system guides at a distance equal to the height of the control panel.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.6. C ONNECTIONS FOR INSTALLATION PERATIONS 1. Check that the general mains switch of the Control panel (CP) is in the OFF position 2.
Page 12
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Dia. 2.6.1 Connections for Pre-installation Operations Schematic Diagram STK3-GMV10 Electric System Page 12 of 76...
Page 13
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Dia. 2.6.2 Connections for Pre-installation Operations Schematic Diagram STK3-GMV10 Electric System Page 13 of 76...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators HAFT OUNTING AND ONNECTIONS 2.7.1 S HAFT HAFT PRIGHT 1. The shaft line is made up of a taped coil of colored or numbered unipolar wires, with insert connectors and labeled for the panel side.
Page 15
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.7.2. S HUNT ONNECTIONS TO THE SHAFT LINE The shunt connections to the line (see the installation schematic diagram) must be performed...
Page 16
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Position the lower and upper parts of the connector… Press the conductors between the rip-resistant clamps … and tighten using a wrench...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.8. C OUNTINGS AND ONNECT IONS 2.8.1. M OUNTING THE CONNECTION BOX AND MAKING FLEXIBLE CABLE CONNECTIONS 1. Attach the connection box using the screws provided 2.
Page 18
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.8.3. S HAFT ITHOUT NCODER ENSORS OUNTING AND ONNECTIONS ESCRIPTION The shaft houses the following sensors: • Two timing devices (SRD, SRS) for the end floor speed change, toggle contacts •...
Page 19
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Connect the impulse generators as shown in the installation schematic drawings Set the operation mode to normal using menu 4.1.1 Service\Operation\Mode .1 Mode..
Page 20
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Dia. 2.8.3.2 Magnet Set-Up Overview for Shaft without Encoder STK3-GMV10 Electric System Page 20 of 76...
Page 21
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.8.4. S HAFT NCODER ENSOR OUNTING AND ONNECTIONS ESCRIPTION The shaft houses the following sensors: • Two timing devices (SRD, SRS) for the end floor speed change, toggle contacts SRS also identifies the unblock zone of the lower end floor for emergency descents •...
Page 22
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Connect the impulse generators as shown in the installation schematic drawings. Set the operation mode to normal using menu 4.1.1 Service\Operation\Mode .1 Mode..
Page 23
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Dia. 2.8.4.2 Magnet Set-Up Overview for Shaft with Encoder STK3-GMV10 Electric System Page 23 of 76...
Page 24
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 6. Perform the self-tuning of the car using menu 4.3.1 Service\Calibraion\Shaft\Encoder .1 Shaft Self- Execute the shaft self-tuning operation. tuning Press ENT to start the operation.
Page 25
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 8. At the end of the operation, the message 'End' will appear on the display if the shaft reading has been performed correctly. Otherwise, under STS the type of error/anomaly found will be indicated.
Page 26
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators DJUSTMENT OF HAFT WITH NCODER Check that the values of the speed change space set in menu 3.3.5 Set-Up\Shaft are suitable for the plant speed with reference to table Tab. 2.8.4.1 or Info.\Speed Change...
Page 27
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Tab. 2.8.4.2 Speed Change Space for Shaft with Encoder and GEV Valve Parameter 3.3.5.1 and Cabin Speed Minimum RS , Parameter (m/s)
Page 28
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators VALVE UNING When first installed and/or when a valve part is replaced, or if the STK3-EV01 board is replaced, the valve must be calibrated using the self-tuning maneuver in menu 4.3.2...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.9. C ONNECTIONS TO ANEL AND OWER 1. Disconnect the Use-Installation button panel of the control panel. 2. Connect the flexible cables and the shaft lifting cable to the control panel according to the installation schematic diagrams.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.10 I SOLATION Prior to performing the Isolation tests shown in the table below, perform the following steps: Stop the cab off floor...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3. PROGRAMMING AND DIAGNOSTICS PT01 P HARACTERISTICS OF THE ROGRAMMER The system is programmed and diagnosed using the PT01 programmer, which has the following specification: •...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators ROGRAMMER ARAMETERS AND The information relative to the configuration of the plant and its diagnostics is organized in parameters which are identified in menus and submenus.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators DENTIFICATION AND CCESS Firmware installed: STK3-GMV 10 Vxx.x Ryy.y Vxx.x : Version Number Ryy.y : Release Number Ý Þ Serial number of the base board GMV 10...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators ABLE 1. Diagnostics....................................36 1.8 Diagnostics\Transducers..............................37 1.9 Diagnostics\Inputs -Outputs ...............................38 1.10 Diagnostics\Counters ...............................40 Alarm Code Table ..................................41 AL01 Board light indicators ..............................46 Signals table and STK3-B board terminals ...........................47 2.
Page 35
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 4 Service ......................................65 4.1 Service\Functioning................................65 4.2 Service\ Commands and Test.............................65 4.3 Service\Taring..................................66 4.3.1 Service\Taring\Shaft Encoder..........................66 4.3.2 Service\Taring\ GEV Self-tuning ..........................67 4.3.3 Service\Taring\ VS Valve ............................67 4.3.4 Service\Taring\Safety Valve.............................67...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators ARAMETERS 1. Diagnostics 1.1 Oper. Status Displays the current operation Normal status: • • Normal Operation Inspection • • Installation Fireman Ý...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 1.8 Diagnostics\Transducers 1.8.1 Oil Temp. Displays the current value of the oil plant temperature xx °C Ý Þ 1.8.2 Oil Pres. Displays the current value of the piston oil pressure xx.x bar...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 1.9 Diagnostics\Inputs-Outputs RD RS ID IS CS M Displays the status of the floor indicators and safety circuit • RD, RS Ascent and Descent re-phase •...
Page 39
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators IA. 210987654321 Displays the status of the Cabin 1 Button Panel call input signals 000000000000 I12…I1 0= Open Contact, 1= Closed Contact Ý...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 1.10 Diagnostics\Counters 1.10.1 Start Asc. Displays the number of ascent starts performed The count is updated every 10 starts. nnnn0 The count cannot be reset Ý...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Alarm Code Table Description Long run timer intervention Long run timer intervention leveling to floor Motor pump/winch thermal sensor intervention Number of re-levelings to floor performed above set limit...
Page 42
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators No closure of the Cab Door Safety Contacts, Floor Door Blocks with the cab moving near stop No closure of the Cab Door Safety Contacts, Floor Door Blocks with the cab moving near stop...
Page 43
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators No recognition of the ID signal at the stop during descent operation, stop 03. No recognition of the ID signal at the stop during descent operation, stop 04.
Page 44
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators No recognition of the ID signal for speed change during descent operation, stop 02 No recognition of the ID signal for speed change during descent operation, stop 03...
Page 45
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Panel temperature above set value Oil temperature out of range for self-tuning Encoder shaft, distance to extreme floor < 300 mm in high speed.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators (*) Alarm type: 1. Permanent alarms (require manual rearm) that shut down the system 2. Permanent alarms (require manual rearm) that shut down the system with cabin at the level.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Signals table and STK3-B board terminals Terminal Function Enable channel 1, controlled by impulse IS and ID Control safety circuit status Power LED, on and steady for correct power, blinking: power out of range...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2. Configuration This menu allows the definition of the plant characteristics which will be detailed on an operative level in menu 3. Set-up.
Page 49
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 2.11 Universal Select type of operation: • Operation Universal, APB • Simplex Descent Ý Þ • Simplex Ascent/Descent Select type of Shaft informer used: 2.12 Shaft Type...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3. Set-up This menu allows the set-up of the specific parameter values for the plant based on the configuration selected in menu 2. Configuration.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.1 Settings \ Valve 3100 .1 Inspect. speed Inspection manoeuvre speed selection (maintenance): • Low speed • High speed .2 Vnom Ascent...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.1 Set-up\Valve GEV Following is the setup of Menu 3.1 when the GEV valve is selected 3.1.1 Set-up \ Valve GEV \ Ascent Set the nominal ascent speed .1 Ascent...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.1.2 Set-up \ Valve GEV \ Descent .1 Descent Set the nominal descent speed Nom Speed:x.xx Values allowed: 0.2 to 1.00 m/s Ý...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.1.3 Set-up \ Valve GEV \ Gains .1 Gain Set Gain P P: x Values allowed: 0…9, standard set-point= 4 Adjusts the response speed of the adjustment Increase if the plant is low, decrease if the plant tends to vibrate Ý...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.2 Set-up\Pressures (with pressure transducer) The display of menu 3.2 is conditioned by the method selected for the pressure control, parameter 2.4.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.3 Set-Up\Shaft Info (Shaft with Contacts without Encoder) (*) The display of menu 3.3 is conditioned by the method selected for the shaft information control, parameter 2.12...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.3 Set-Up\Shaft Info (Shaft with Encoder) 3.3.1 Set-up\Info. Shaft\Distance Type Floors 01 <> 02 Select the type of distance between floors 01<>02, 02<>03, … 11<>12.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.3.5 Set-up\Info. Shaft\Speed Changes (with valve GEV and 3010) .1 Ascent Set the speed change distance referred to the nominal ascent speed...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.4 Set-up\Floors 3.4.1 Set-up\Floors\Main .1 Floor Set the Main Floor position. 3.4.2 Set-up\Floors\Firemen .1 Floor Set the Fireman Floor position. 3.4.3 Set-up\Floors\Parking .1 Floor...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.5 Services 3.5.1 Settings\Services\Reset .1 Reset? Reset services configuration and parking/opening to the following values: • ESC=NO Cabin: I1…I12 Like Insides Side A 1…12 •...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.5.4 Set-up\Services\External Expansion .1 Input: E13 Allows the association of each input, ES1 to ES12 to the relative External xx y servi ce, in terms of floor and opening side.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.6 Set-up\Indicators 3.6.1 Set-up\Indicators\Display .1 Display Select the floor number shown on the cabin and floor display. Floor 01: 01 Possible floors associable with each floor: •...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.7 Set-up\Alarms .1 Room Set the Excess Room Temperature Alarm Temperature: xx Setting value 0 disables the alarm ºC Ý Þ .2 On floor...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 3.8 Set-up\Timer 3.8.1 Stopping Set the stopping time at a floor after the doors open Timer Is annulled by a Cabin call and, when calls are registered, by the close : xx s door button.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 4 Service 4.1 Service\Functioning .1 Mode. Set the functional mode for the elevator Normal Allowed values: • Normal • Installation 4.2 Service\Commands and Test .1 Calls...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 4.3 Service\Taring 4.3.1 Service\Taring\Shaft Encoder This function is only enabled if the shaft with encoder type has been selected in parameter 2.12. Otherwise...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 4.3.2 Service\Taring\GEV Self-tuning This function is only enabled if the shaft with GEV valve type has been selected in parameter 2.3. Otherwise the following message will be displayed: Not required! ..2 Self-tuning...
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 4.4 Service\Programming 4.4.1 Service\Programming\Inputs This menu allows the operations to be performed by each individual programmable input to be set Each function can be used with activation by either Normally Open (NO) or Normally Closed (NC) contacts.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 4.4.4 Service\Programming\Reset 1 .1 Reset? Total reset of configuration relative to a standard system After this operation, the programming must be done for the specific system...
Page 70
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Table 1. Currently Allowed Input Functions Displayed Symbol Function FUN 00 No function selected, input not used FUN 01 NC FUN 01 NO Funct.
Page 71
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators Table 2. Currently Allowed Output Functions Displayed Symbol Function FOUT 00 Function 00: No function, output inactive FOUT 01 Function 01: Opening I command op.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 4.5 Service\Language .1 Language? Selection of language to be used on the keypad The allowed options depend on the software installed. English 4.6 Service\Safeties...
During maintenance operations refer to the safety precautions outlined in Paragraph 2. SEA SYSTEMS S.r.l. declines all responsibility due to the disregard of the instructions listed below and for any alterations, attachments, or connections which do not comply with original supply of the equipment.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 4.3. R STK3-B B EPLACEMENT OF THE ASIC LECTRONIC OARD CAUTION The GMV 10 board contains circuits connected to the safety chain exclusively for monitoring information in compliance with the harmonized standard EN 81.
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators SOLUTIONS TO MOST FREQUENT PROBLEMS 5.1. STK3-B B (ALARM LED OARD IN LARM Should the board be in alarm (the red ALARM LED is on), find the error code using the PT01 programmer (see Breakdown Code Table in Menu PT01 1.Diagnostics).
INSTALLATION AND USE MSTK3-GB Rev.03 STK3-GMV10 Control panel and Pre-wiring SEA SYSTEMS 20/07/09 For Hydraulic and Traction Elevators 6. TECHNICAL SPECIFICAT ION Type of electric system logic Distributed with serial connection Type of control Microprocessor Input Voltage From 110 to 440 V AC (Single- and three-phase)
Need help?
Do you have a question about the STK3-GMV10 and is the answer not in the manual?
Questions and answers