Master On/Off Switch (Late Models) - Bunn U3 Operating & Service Manual

Bunn u3, u3a operating & service manual
Table of Contents

Advertisement

SERVICE (cont.)

MASTER ON/OFF SWITCH (Late Models)

FIG. 36 MASTER ON/OFF SWITCH LOC.
Location:
The Master ON/OFF switch is located in the top hous-
ing at the rear, FIG. 36.
Test Procedure:
1.
Disconnect the brewer from the power source
and remove the wires from all terminals of the
Master ON/OFF switch.
2.
Check for continuity across the two terminals on
the switch at L1 BLK and BLK to Main Harness
when it is held in the lower position, Fig. 32.
Check for continuity across the two terminals on
the switch at L2 RED and RED to Main Harness
when it is held in the lower position.
Continuity must not be present across these
terminals in the upper position.
If continuity is present as described, reconnect the
wires, the switch is operating properly.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1.
Remove all wires from the switch terminals.
2.
Remove the two screws from the outside of the
base and gently push the switch through the
opening.
3.
Locate the new switch into the opening and se-
cure with screws removed in step 2.
4.
Refer to FIG. 37 when reconnecting the wires.
Incoming Power Supply
L1 - BLK
P1752.55
L2 - RED
Main Wiring harness
BLK
RED
FIG. 37 MASTER ON/OFF SWITCH WIRING
Page 36
P3955
10060 011708

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

U3a

Table of Contents