Table Of Contents - ABB RELION REB500 Communication Protocol Manual

Distributed busbar protection
Hide thumbs Also See for RELION REB500:
Table of Contents

Advertisement

1MRK 511 450-UEN Rev. C

Table of contents

Section 1
Introduction.................................................................................................... 3
1.1
This manual....................................................................................................................................3
1.2
Intended audience........................................................................................................................ 3
1.3
Revision history.............................................................................................................................3
1.4
Product documentation.............................................................................................................. 3
1.5
Symbols and conventions...........................................................................................................4
1.5.1
Symbols........................................................................................................................................ 4
1.5.2
Document conventions............................................................................................................. 4
Section 2
Safety information......................................................................................... 5
Section 3
Interbay bus functions...................................................................................7
3.1
Introduction................................................................................................................................... 7
3.2
Basic configuration...................................................................................................................... 7
3.3
Configuring IEC 61850-8-1 IBB................................................................................................ 10
3.3.1
Station protection specific signals.......................................................................................10
3.3.2
Logical node GGIO (Generic process I/O) configuration..................................................11
3.3.3
Bay protection specific signals..............................................................................................13
3.4
Transfer of differential current values................................................................................... 15
3.4.1
The delta/dead band algorithm............................................................................................ 15
3.4.2
Configuring the SCS differential current parameter.........................................................15
Section 4
IEC 61850-8-1.................................................................................................17
4.1
Introduction................................................................................................................................. 17
4.2
Modeling in logical devices....................................................................................................... 17
4.3
Mapping of the REB500 signals to logical nodes................................................................. 17
4.3.1
Station protection specific signals....................................................................................... 17
4.3.2
Bay protection specific signals............................................................................................. 20
4.4
Differential currents...................................................................................................................22
4.5
Disturbance recorder.................................................................................................................23
4.6
User activity events.................................................................................................................... 23
4.7
Service tracking (LTRK)............................................................................................................. 23
4.8
GOOSE supervision (LGOS)...................................................................................................... 24
4.9
Creation of the *.IID file.............................................................................................................24
4.10
Redundant interbay bus............................................................................................................24
4.11
Source information for LLN0.Health and LPHD.PhyHealth............................................... 24
Distributed busbar protection REB500
Communication protocol manual IEC 61850
© 2019 - 2020 Hitachi Power Grids. All rights reserved
Table of contents
1

Advertisement

Table of Contents
loading

Table of Contents