SERVICE (cont.)

Solenoid Valve

Location:
The solenoid valve is located inside the rear of the dis-
penser on the right side near the bottom.
To test the solenoid valve, access will also be needed
to the electronic control assembly.
Fi ll
!
W A
wa
th er
te r
R N
m os
ta nk
to
po
ta t
IN G
Us
we
or
be
e on
r so
co
fo re
ci rc
ly
ur ce
nn
tu rn
ui t
on
ec
in g
El ec
ca
a pr
.
tin
g ap
-o n
tri ca
pa
op
Fo
lly
bl e
er ly
pl ia
llo
w
gr ou
of
th e
pr ot
nc
e
Do
na
no
t us
tio
nd
ra te
ec
te d
FA
na
l/l oc
th e
d lo
IL UR
e ne
ch
ad
E TO
ar
al
el ec
as
si s.
.
DA
co
m bu
M AG
CO
tri ca
RE
E,
M PL
st ib
l co
AD
FI RE
Y RI
le s.
de
LIA
IN
CL
TH
, OR
s.
BI LIT
UD
E EN
SK
S EQ
Y BE
IN
G
TI RE
SH
FO
TH
OP
OC
UI PM
TH
RE
E LIM
ER
K HA
IS
AP
BU
IT
AT
ZA
EN
T
CO
PL
YI NG
OF
IN
G
RD
NN
IA NC
OR
W AR
MA
008
EC
E IS
US
RA
NU
31.0
000
TE
D
HE
IN
NT
AL
A
5/88
TO
AT
G
TH
Y AN
©
A PO
ED
IS
D
198
8
W ER
W HE
PR
BUN
N-O
NE
OD
UC
-MA
TIC
SO
VE
T
COR
UR
CE
R
POR
ATI
ON
FIG. 10 SOLENOID VALVE
Test Procedure:
1. Disconnect the dispenser from the power source
and turn-off the water supply to the dispenser.
2. Remove the pink wire from terminal 5 of the elec-
tronic control assembly.
3. Check the voltage across the solenoid valve coil
terminals with a voltmeter. Connect the dispenser
to the power source. The indication must be:
a.) 100 to 120 volts ac for 100 to 120 volt models
or
b.) 200 to 240 volts ac for 200 to 240 volt models
after a delay of approximately 5 seconds.
4. Disconnect the dispenser from the power source.
If voltage was present as described, proceed to #5.
If voltage was not present as described, refer to the
Wiring Diagrams and check the dispenser wiring har-
ness.
5. Remove both wires from the solenoid valve coil
terminals.
6. Check for continuity across the solenoid valve coil
terminals.
If continuity is present as described, reconnect the
wires and proceed to #7.
If continuity is not present as described, replace the
solenoid valve coil.
7. Check the solenoid valve for coil action. Connect
the dispenser to the power source. Listen carefully
in the vicinity of the solenoid valve for a "clicking"
sound after approximately 5 seconds, as the coil
magnet attracts the plunger.
8. Disconnect the dispenser from the power source.
9. Reconnect the pink wire to terminal 5 of the elec-
tronic control assembly.
If the sound was heard as described and water will not
pass through the solenoid valve, there may be a block-
age in the water line before or after the solenoid valve
or the solenoid valve may require inspection for wear
and removal of waterborne particles.
If the sound was not heard as described, replace the
solenoid valve.
Removal and Replacement:
1. Remove all wires from the solenoid valve coil.
P1778
2. Turn-off the water supply to the dispenser.
3. Disconnect the water lines to and from the sole-
noid valve.
4. Remove the two 8-32 slotted-head screws holding
the solenoid valve and mounting bracket to the
component bracket.
5. Lift-out the solenoid valve.
6. Remove the two 10-32 slotted-head screws hold-
ing the solenoid valve to its mounting bracket.
7. Securely install the new solenoid valve to its mount-
ing bracket. The direction of flow arrow must be
pointing towards the tank lid.
8. Attach the solenoid valve and mounting bracket to
the component bracket.
9. Securely fasten the water lines to and from the so-
lenoid valve.
10. Reconnect the wires, FIG. 11.
FIG. 11 SOLENOID VALVE WIRING
18
WHI/BLU to Electronic Control #1
WHI or RED to Terminal Block
10420 011599
P1779

Hide quick links: