Sony DSC-RX100M4 Service Manual page 18

Hide thumbs Also See for DSC-RX100M4:
Table of Contents

Advertisement

Self-diagnosis Code
Block
Detailed
Function
Code
E
6 1
1 0
E
6 1
3 0
E
6 2
0 2
E
6 2
1 0
E
6 2
1 1
E
6 2
1 2
E
6 2
2 0
E
9 1
0 1
E
9 2
0 0
E
9 4
*3
0 0
*1:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items. After
the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
*2:
After check, be sure to perform
*3:
Function of this code is not provided in this unit.
DSC-RX100M4
Symptom/State
Zoom operations fault
(Cannot initialize zoom lens)
Reset position detection error on the
stepper iris initializing
Abnormality of IC for steadyshot.
Shift lens initializing failure
Shift lens overheating (PITCH)
Shift lens overheating (YAW)
Abnormality of thermistor
Abnormality when flash is being
charged
Battery/Dry cell distinction defect
Fault of writing or erasing the inter-
nal memory
"1-2. Process after Fixing Flash
Correction
Turn power off and turn power on again. When this error is
not cleared, operate the zoom lever and check following
items.
When zooming is performed, the zoom control signal
for the lens block may be faulty.
When zooming is not performed, the zoom motor
drive circuit may be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
Turn the power on to open lens barrier. Disconnect the bat-
tery or power cord, and then connect again. And confirm
that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive cir-
cuit in lens drive block. If iris blades work normally, con-
firm that they are closing completely and confirm following
items.
Case of the iris blades do not close normally. Replace
the lens block.
Case of "E: 61: 30" is appeared and iris blades closed
completely. Confirm that communication with lens
block is normal.
Case of LCD is not displayed normally, check that
connection between imager board and main board.
Case of LCD is displayed normally, replace the lens
block.
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, replace the
board that contains this peripheral circuit.
Replacement of lens block.
If an error occurs again, steadyshot circuit may be faulty.
Replace the board that contains this peripheral circuit.
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board. Replace
the faulty lens or board.
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board. Replace
the faulty lens or board.
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board. Replace
the faulty lens or board.
Checking of flash unit or replacement of flash unit.
Turn power off and turn power on again.
Turn power off and turn power on again.
Error".
*1
*2
Continued
1-2