INSTALLATION OF THE DUCTING VERSIONS
Install the wiring system and prepare the air venting hole (Fig. 2).
Insert the appliance in the hole (Fig. 4).
Tighten the 2 screws inside the appliance (Fig. 6) until it fits snug on the bottom of the wall unit. Do not tighten the two screws
strongly to maintain the two metallic clamps in the right position.
To get optimal conditions the air venting pipe should: be as short as possible, have the lowest number of bends (max bende angle:
90°), be made of material approved by local authorities (according to the State), have its inner side as regular and smooth as
possible. It is moreover recommended to avoid drastic changes of pipe cross section (recommended diameter: 150 mm). The
device is provided with a 150-125 cm reduction.
Connect the air exit tube with the device air outlet (Fig. 2): use a flexible tube and stop it in the device air outlet through a metallic
clamp (tube and clamp are not provided).
Remove the charcoal filter by placing pressure on the clamp located on the interior of the hood and rotating it until the two tabs
are removed from position (Fig. 7).
Fig. 7
Make the electrical connection of the hood by means of the power supply cable.

DEVICE DISASSEMBLY

Remove the grease filter.
During the following operations always support the device.
Tighten the 2 screws inside the device (Fig. 6); moving
the 2 small tongues toward the device inside using the
right carvings (Fig. 8); pull out the device from its side.
Fig. 8