Lotus cooker FVD-78ETX Instructions For Installation And Use Manual page 21

Electric oven for professional use
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 for the
gas part and with norm 2006/95/CE, 2004/108/CE for the electric part. The installation must be done observing the
norms in force particularly concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
MODELS
FSD-78ET
FSD-98ET
FVD-78ET
FVD-78ET
On positioning the appliance, ensure that it is perfectly levelled. Small adjustments can be made by screwing the
adjustable feet up or down. The master switch or the socket point must be in proximity to the appliance and easily
accessible. It is advisable to place the oven under an extractor hood to ensure rapid elimination of steam. If the
appliance is placed near a wall or partition, kitchen furniture or decorative coverings, etc., these must be fire-proof or
coated with fire-proofing. Local fire prevention regulations must be observed. There must be maximum clearance
between the front edge of the cabinet and the appliance.
REGULATIONS, TECHNICAL STANDARDS AND SPECIFICATIONS
Installation must be carried out in accordance with:
current accident prevention legislation;
current VDE specifications.
The installation, start-up and maintenance of this appliance must be carried out only by qualified fitters. All installation
operations must be in accordance with current regulations. The manufacturer declines all responsibility for
malfunctioning due to bad or faulty installation.
Attention: international regulations require that a omni pole cut-out device with contact opening of at least 3 mm be
fitted on the wiring leading to the appliance.
The terminal board is situated behind the front panel. The electrical wiring must be no less than HO5 RN F and have a
section suitable for the appliance (see 1.1). Secure the wiring with the wiring clips. Connect the wire ends to their
terminals on the terminal board. The earthing wire must be longer than the other wires so that it will disconnect after the
live wires in the event of the fastener breaking.
The appliance is designed to be connected to a unipotential system. The connecting screw is situated on the back of the
appliance and is identified by an adhesive
Attention: the manufacturer cannot be held responsible for, and does not cover in the guarantee any damage resulting
from bad or faulty connections.
GB
DECLARATION OF COMPLIANCE
ELECTRICAL DATA
MAXIMUM
POWER SUPPLY
POWER KW
El. oven GN1/1
400V~3N 50/60Hz
400V~3N 50/60Hz
400V~3N 50/60Hz
230V~3 50/60Hz
POSITIONING
INSTALLATION
ELECTRICAL CONNECTION
EQUIPOTENTIAL
IE
MAXIMUM
ABSORPTION A
5
10,43
6,7
14,78
5,32
8,06
5,32
13,35
label.
18
POWER
SUPPLY CABLE
5 x 1,5
5 x 2,5
5 x 1,5
4 x 2,5

Advertisement

Table of Contents
loading

Table of Contents