Installation - tau K590M Installation Manual

Hide thumbs Also See for K590M:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
WARNINGS
This manual has been especially written for use by qualifi ed fitters. No information given in this manual
can be considered as being of interest to end users. This manual is enclosed with control unit K590M and
may therefore not be used for different products!
Important information:
Disconnect the panel from the power supply before opening it.
The K590M control unit has been designed to control an electromechanical gear motor for automating
gates and doors of all kinds.
Any other use is considered improper and is consequently forbidden by current laws.
Please note that the automation system you are going to install is classifi ed as "machine construction"
and therefore is included in the application of European directive 2006/42/EC (Machinery Directive).
This directive includes the following prescriptions:
-
Only trained and qualified personnel should install the equipment;
-
the installer must first make a "risk analysis" of the machine;
-
the equipment must be installed in a correct and workmanlike manner in compliance with all the
standards concerned;
-
after installation, the machine owner must be given the "declaration of conformity".
This product may only be installed and serviced by qualified personnel in compliance with current, laws,
regulations and directives.
When designing its products, TAU observes all applicable standards (please see the attached declaration
of conformity) but it is of paramount importance that installers strictly observe the same standards when
installing the system.
Unqualified personnel or those who are unaware of the standards applicable to the "automatic gates
and doors" category may not install systems under any circumstances.
Whoever ignores such standards shall be held responsible for any damage caused by the system!
Do not install the unit before you have read all the instructions.

INSTALLATION

Before proceeding, make sure that the gate opens and closes easily without mechanical impedi-
ments of any kind. Also check that the gear motor assembly has been installed according to the
instructions and also that the relative rack has been installed on the gate so as not to create
mechanical obstacles during opening and closing.
THE EQUIPMENT MUST BE INSTALLED "EXPERTLY" BY QUALIFIED PERSONNEL AS REQUIRED BY LAW.
Note: it is compulsory to earth the system and to observe the safety regulations that are in
force in each country.
IF THESE ABOVE INSTRUCTIONS ARE NOT FOLLOWED IT COULD PREJUDICE THE PROPER WORKING
ORDER OF THE EQUIPMENT AND CREATE HAZARDOUS SITUATIONS FOR PEOPLE. FOR THIS REASON
THE "MANUFACTURER" DECLINES ALL RESPONSIBILITY FOR ANY MALFUNCTIONING AND DAMAGES
THUS RESULTING.
1. CONTROL PANEL FOR ONE 230V AC MOTOR
MICROPROCESSOR-CONTROLLED LOGIC
INPUT STATUS LED'S
LINE INPUT FUSE
BUILT-IN FLASHING LIGHT CIRCUIT
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
OPERATING TIME FIXED AT 120 sec.
AUTOMATIC DETECTION OF THE POWER SUPPLY FREQUENCY (50 or 60 Hz)
MOTOR TORQUE CONTROL AND OBSTACLE DETECTION BY MEANS OF ENCODER
ADJUSTABLE DECELERATION
"SLOW-DOWN" FUNCTION IN OPENING AND IN CLOSING PHASE
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
14

Advertisement

Table of Contents
loading

Table of Contents