OPERATIONS CHECK
You should familiarise yourself with the operation of the lock and
check that all parts work properly.
Remove the battery cover from the back plate and install the 4 x AA
cells supplied.
Connect the cables from the front plate and back plate. A BEEP
should be heard when you do this. If no BEEP is heard then check
that the batteries are correctly installed.
N.B. The 5010BB is supplied with batteries already installed. See
CL5010BB Installation Step 7 on page 9 for changing the batteries.
Place the long spindle in the front plate socket and using finger
grip only, test that the spindle is easily moved 80° in both
directions. Leave socket in the centred position.
Enter the factory Master Code #1234.
The Blue LED should flash and the spindle should not turn as
before. After 5 seconds the Red LED should flash and the spindle
should turn easily again. This confirms that the clutch engaged
correctly when the code was entered.
N.B. When the Master Code is entered 3 times consecutively
without performing a programming function, a penalty time of 10
seconds is activated.
Disconnect the cables.
For the CL5020 locks see page 10 to check the operation of the
mortice lock.
4
SPECIAL FIXING NOTE
REMOTE RELEASE OPTION
Cables are provided for the REM 1 and REM 2 terminals on the
circuit board (Fig 1).
FIG. 1
1. Battery
2. REM 1
3. REM 2
4. Clutch/Actuator
REM 1 is for connection to a reception desk push button or a door
intercom system. Pressing the button will cause the Blue LED to
flash on the lock and release the lock for the pre-set time.
REM 2 is for connection to the building alarm system to release
a door in an emergency. This allows rooms, wards, offices to be
easily checked to ensure that no person is trapped or overlooked
during an emergency evacuation. When activated REM 2 will
maintain the unlocked condition for 30 minutes, the Red LED will
flash and BEEP during this time.
The lock will automatically lock again after 30 minutes. If
necessary Program 11 can be used to re-lock before the end of the
30 minutes.
REM 1 and REM 2 do not require additional power. They are
normally open contacts requiring a momentary or maintained
signal to close.
DIMENSIONS
CL5010, CL5010BB LATCH FUNCTION
Outside handle turns freely without operating the latchbolt.
When the code is entered the Blue LED flashes and the handle
will retract the latchbolt. The latch automatically locks the door
when closed. The key will open the door without the code.
CL5010
CL5010BB
Front depth off door: 80mm (3 ")
Front depth off door: 80mm (3 ")
CL5020 ANTI-PANIC LOCK FUNCTION
Outside handle and key functions as CL5010. Lockcase key will
double-throw the deadbolt, retract the deadbolt and retract the latchbolt
without the code. When deadbolt is thrown it denies access by code.
The anti-panic feature allows the inside handle to simultaneously
retract the latchbolt and the deadbolt preventing people being
accidentally locked in.
CL5020
84
Front depth off door: 80mm (3 ")
84
FIRE KIT
A Fire Kit pack is available for the CL5010, and when fitted,
they can be installed on 30 or 60 minute fire doors.
Tested in accordance with BS3N1634-1:2008
For more information about this pack please contact Codelocks
84
www.codelocks.com
5