Copyright 2005© Siemens AG

7 VIBRA TRANSISTOR

Fault Symptoms
Customer:
Vibra permanent works
not okay
Exchange
Vibra Transistor
VIBRA Transistor (V211)
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components!
Resolder new component afterwards.
E-commerce order number:
Soldering temperature:
IRIS Diagnose Code:
Service Repair Documentation Level 2.5 - CF62, CF62R, CF63
Vibra
Problems
Watch for oxidation and
damaged pads of the Vibra
Transistor
Check the status of the
Vibra Transistor visually /
electrically
Perform the resistor test
with an Ω-multimeter.
Check the connection
not okay
between the component
parts and the soldering
contacts. The value
must be 0 Ω.
L36810-C6144-D670
240 - 255°C
75400 Acoustics / Vibra / Electrical Damage
Page
GRT:
Tbd.
not okay
okay
okay
okay
of
10
10
s Com
SCRAP
has to be
send separately to
WSC
- check for twisted or
bended contacts
- check for dry joints
Level 2 Repair

Advertisement

loading

This manual is also suitable for:

Cf62rCf63