HANYOUNG NUX MP3-4 H Series Instruction Manual page 3

Digital frequency meter

Advertisement

Digital frequency meter
MP3-4H, MP6-4H
INSTRUCTION MANUAL
Thank you for purchasing HANYOUNG product.
Please check whether the product is the exactly same as you ordered.
Before using the product, please read this instruction manual carefully.
Please keep this manual where you can view at any time
Safety information
Before using the product, please read the safety information thoroughly and use it properly.Alerts declared in the manual
are classified to Danger, Warning and Caution by their criticality
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
WARNING
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury
Danger
There is a danger of occurring electric shock in the input/output terminals so please never let your body or conductive substance is touched.
Warning
•This product does not contain an electric switch or fuse, so the user needs to install a separate electric switch
or fuse externally. (Fuse rating : 250 V 0.5 A)
•To prevent defection or malfunction of this product, apply a proper power voltage in accordance with the rating.
•To prevent electric shock or malfunction of product, do not supply the power until the wiring is completed.
•Since this product is not designed with explosion-protective structure, do not use it any place with flammable or explosive gas.
•Do not decompose, modify, revise or repair this product. This may be a cause of malfunction, electric shock or fire.
•Reassemble this product while the power is OFF. Otherwise, it may be a cause of malfunction or electric shock.
•If you use the product with methods other than specified by the manufacturer, there may be bodily injuries or property damages.
•There is a possibility of occurring electric shock so please use this product after installing it onto a panel while it is operating.
Caution
•The contents of this manual may be changed without prior notification.
•Do not use this product at any place with occurring corrosive (especially noxious gas or ammonia) or flammable gas.
•Do not use this product at any place with direct vibration or impact.
•Do not use this product at any place with liquid, oil, medical substances, dust, salt or iron contents.(Use at Pollution level 1 or 2)
•Do not polish this product with substances such as alcohol or benzene. (Use neutral detergent.)
•Do not use this product at any place with a large inductive difficulty or occurring static electricity or magnetic noise.
•Do not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation.
•Install this product at place under 2,000 m in altitude.
•When the product gets wet, the inspection is essential because there is danger of an electric leakage or fire.
•If there is excessive noise from the power supply, using insulating transformer and noise filter is
recommended. The noise filter must be attached to a panel which is already connected to a ground
and the wire between the filter output side and power supply terminal must be short as possible.
•If twisting the power cables closely together then it is effective against noise.
•Do not connect anything to the unused terminals.
•After checking the polarity of terminal, connect wires at the correct position.
•When this product is connected onto a panel, use a circuit breaker or switch approved with IEC60947-1 or IEC60947-3.
•Install a circuit breaker or switch at near place for convenient use.
•For the continuous and safe use of this product, the periodical maintenance is recommended.
•Some parts of this product have limited life span, and others are changed by their usage.
•The warranty period for this product including parts is one year if this product is properly used.
Suffix code
Model
Code
MP
Digital frequency meter
3
Dimension 96 × 48 ㎜
Dimension
6
Dimension 72 × 36 ㎜
Displayable digit
4
4 digits (9999)
N
Only for display
0
Relay output (HI, GO, LO) + Current output (4 - 20 ㎃)
Output (Optional)
1
Relay output (HI, GO, LO)
2
NPN TR output (HI, GO, LO) + Current output (4 - 20 ㎃)
3
PNP TR output (HI, GO, LO) + Current output (4 - 20 ㎃)
Measurement input signal
H
AC input frequency measurement
※ Measurement input signal is confined to MP6-4H and MP3-4H is under developed
Specification
Power supply voltage 100 - 240 V a.c 50 - 60 ㎐ allowable voltage fluctuation : 85 ~ 110 %
Power consumption 5 VA
Display method
7 Segment LED Display
Insulation resistance 100 min ㏁ (500 V d.c mega standard) between the external terminal and case
Dielectric strength
2000 V a.c for 1 min (between the external terminal and case)
Noise immunity
Square wave noise by the noise simulator pulse width 1 ㎲, ±1000 V
Malfunction 10 -55 Hz peack amplitude 0.5mm X/Y/Z each direction for 1 hour
Vibration resistance
Resistance 10 -55 Hz peack amplitude 0.5mm X/Y/Z each direction for 2 hours
Malfunction 100 ㎨ X·Y·Z each direction for 3 times
Shock resistance
Resistance 300 ㎨ X·Y·Z each direction for 3 times
Ambient temperature -10 ~ 55 ℃ (icing or dew condensation not allowed)
Ambient humidity
35 ~ 85 % RH (without dew condensation)
Storage temperature -20 ~ 65 ℃ (icing or dew condensation not allowed)
Relay Life span
Phisical : 20,000,000 ㎰ Min , Electrical : 100,000 ㎰ Min
Measurement method Coefficient Measuring method
When the input period is less than 0.1 second, it displays every 0.1 second.
Display cycle
When the input period exceeds 0.1 second, it displays every 0.1 second.
Displayable digit
-1999 ~ 9999 (4 digits)
Measurable range
0.1 Hz - 9999 Hz
Measuring items
Frequency (Hz)
Decimal function
Selection by internal parameter
Scaling function
Displaying function of converting measured maximum value and minimum value into random figure
Hold function
External hold automatic hold of peak detection for maximum value and minimum value
Control
Hold of Displaying value
•Comparative output
Other functions
•Protect the set value from changing •Average the value and delay the display cycle
·Relay output of contact point (3 output)
Output (Optional)
·Current output (4 - 20 ㎃)
Weight
Approx. 180 g
Information
•Max value / min value indication by the front key
·Transistor output (NPN, PNP)
HANYOUNGNUX CO.,LTD
1381-3, Juan-Dong, Nam-Gu Incheon, Korea.
HEAD OFFICE
TEL:(82-32)876-4697 FAX:(82-32)876-4696
http://www.hynux.net
PT. HANYOUNG ELECTRONIC INDONESIA
JL.CEMPAKA BLOK F 16 NO.02 DELTA SILICON II INDUSTRIAL PARK
INDONESIA
LIPPO CIKARANG CICAU, CIKARANG PUSAT BEKASI 17550 INDONESIA
FACTORY
TEL : 62-21-8911-8120~4 FAX : 62-21-8911-8126
Connection diagram
● MP3-4-NH
▒ MP3-4-OH
(Relay output, 4 - 20 mA Current output)
▒ MP6-4-OH
(Relay output, 4 - 20 mA Current output)
▒ MP6-4-2H
(NPN TR, 4 - 20 mA Current output)
Parameter 1
Display
Mode name Default value
Input range
Factor
Input
compensation
Updating
cycle
High scale
Low scale
Position of
decimal point
Hold function
Lock function
Parameter 2
Display
Mode name Default value
High Peak
Display
Low Peak
Display
Output
High Set
Output
Low Set
Output Type
Select
HYS terisis
3
MF0104KE130121
● MP6-4-NH
▒ MP3-4-1H
(Relay output)
▒ MP6-4-1H
(Relay output)
▒ MP6-4-3H
(PNP TR, 4 - 20 mA Current output)
Set range
0
1
Select the measuring range of
input frequency.
2
3
Max :
Use this to get the ×(involution)
of input reading.
Min :
Max :
Correct the error by adding(+) or
reducing(-) to the input reading.
Min :
Max :
Set up the time for measure the
mean value of input.
Min :
Set up the maximum value
Max :
of display when you need to
Min :
convert into random value.
Set up the minimum value of
Max :
display when you need to
Min :
convert into random value.
Set up the location of
a decimal point
Set up the autonomic holding
when detecting PEAK value.
Use external hold (E-Ha)
Set up the locking on function of
panel meters
Set range
Display the max value
-
-
among the measured values.
Display the min value
-
-
among the measured values.
Max : +9999
Set up the high set value.
Min : -1999
Max : +9999
Set up the low set value.
Min : -1999
LL(LL.ot)
HH(HH.ot)
Set the comparative output
LH(LH.ot)
mode.
HL(HL.ot)
IL(IL.ot)
Max : 99
Set up the hysteresis.
Min : 00
Remark