Install The Plumbing; Make Electrical Connections - Kohler К-1643 Installation Manual

Sonata bath/shower module with whirlpool
Table of Contents

Advertisement

Available languages

Available languages

4. Install the Plumbing

CAUTION: Risk of property damage. Ensure a watertight seal on the whirlpool drain.
- Connect the drain to the trap according to the drain manufacturer's instructions.
NOTICE: An access panel will simplify future maintenance.
- Install the shower, fill spout, valving, and supply connections. Strap the supply connections to the stud framing. Provide
access to the connections for future maintenance. Install the trim.
- Connect the drain to the trap.
- Open the hot and cold water supplies, and check the connections for leakage. Install the faucet trim according to the
manufacturer's instructions.
- Run water into the whirlpool, and check the drain connections for leakage.

5. Make Electrical Connections

WARNING: Risk of electrical shock. To reduce the risk of electrical shock, connect the pump and in line heater (if heater
option included) to properly grounded, grounding type receptacles protected by Ground Fault Circuit Interrupters
(GFCI's). Do not remove the plugs' grounding pins. Do not use grounding adapters.
Pump Wiring
NOTE: The whirlpool model number is printed on a label near the whirlpool pump. This label also identifies the electrical
rating of the whirlpool.
- Your Kohler whirlpool bath is equipped with a cord and plug. All wiring of the pump and control has been completed at the
factory. A licensed electrician must install a GFCI protected, 120 V, 15 A, grounded outlet. No other load should be on this
circuit. Locate the outlet behind the whirlpool, and within 24" (61cm) of the pump.
- Plug the pump into this outlet.
NOTE: Make sure the air actuator tubing is securely attached to the pump, and is not kinked or damaged.
- If a K 1639 Timer Kit will be used, install it now according to the instructions packed with the timer kit.
In-line Heater Wiring
- H" Models: The in line heater is equipped with a cord and plug. All wiring of the heater has been completed at the factory.
A licensed electrician must install a GFCI protected, 120 V, 15 A, grounded outlet. No other load should be on this circuit.
Locate the outlet behind the whirlpool, and within 24" (61cm) of the heater.
- Plug the in line heater into this outlet.
Kohler Co.
Plug the in-line heater
into this outlet.
7
Plug the pump into this outlet
Install a GFCI-protected 120 V, 15
A grounded outlet. Install a second
GFCI-protected outlet for "H"
models for the in-line heater.
Bond in accordance
with applicable codes
Make sure air actuator tubing is
securely attached to the pump