Install The Plumbing - Standard - Kohler K-1110 Installation Manual

Bath with airjets
Hide thumbs Also See for K-1110:
Table of Contents

Advertisement

Available languages

Available languages

Secure to the Subfloor - Standard (cont.)
Remove the protective tape from the rim.
Apply a continuous bead of silicone sealant around the entire rim of the bath. Allow the sealant to
cure as per the manufacturer's instructions.
Silicone Sealant Method
With help, carefully move the bath into the installation area.
Verify the leveling blocks are resting directly on the subfloor. Reposition or shim as needed.
Verify the bath is level across the top of the bath. If the bath is not level, shims must be used under
the bath.
Connect the drain tailpiece to the trap.
Remove the protective tape from the rim.
Apply a continuous bead of silicone sealant around the entire rim of the bath. Allow the sealant to
cure as per the manufacturer's instructions.

5. Install the Plumbing - Standard

CAUTION: Risk of property damage. A watertight seal must exist on all bath drain connections.
The watertight seal will prevent property damage.
Connect the drain to the trap according to the drain manufacturer's instructions.
NOTE: To simplify future maintenance, provide access to all plumbing connections.
Install the faucet valving according to the faucet manufacturer's instructions. Do not install the
faucet trim until instructed. Open the hot and cold water supplies, and check the supply
connections for leakage.
Run water into the bath, and check the drain connections for leakage.