ECOFOREST ecoSMART Supervisor User, Installer And Technical Service Manual

ECOFOREST ecoSMART Supervisor User, Installer And Technical Service Manual

Advertisement

ecoSMART Supervisor
USER, INSTALLER AND TECHNICAL SERVICE MANUAL
EN
MODEL:
SERVICE CONTACT:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ecoSMART Supervisor and is the answer not in the manual?

Questions and answers

Summary of Contents for ECOFOREST ecoSMART Supervisor

  • Page 1 Supervisor USER, INSTALLER AND TECHNICAL SERVICE MANUAL MODEL: SERVICE CONTACT:...
  • Page 3: Table Of Contents

    Supervisor user, installer and technical service manual Contents General information ................................5 1.1. Safety considerations ................................5 1.2. Recycling ....................................6 1.3. Maintenance ................................... 7 General description ................................. 7 Installation ....................................7 3.1. Transport and handling ................................7 3.2.
  • Page 4 Supervisor user, installer and technical service manual 10. Warranty and technical service .............................. 38 10.1. Manufacturer's warranty ..............................38 10.2. Authorised distributors and technical service ........................38...
  • Page 5: General Information

    Supervisor user, installer and technical service manual 1. General information Thank you for purchasing an ecoGEO HP heat pump cascade system. This manual contains information about installing, commissioning and troubleshooting the device. There is also useful information for the end user, such how to navigate and adjust parameters via the control panel.
  • Page 6: Recycling

    DANGER! Ecoforest recommends installing an automatic external switch for each of the electrical power sources (power supply of the supervisor and power supply of devices controlled by its DO digital outputs).
  • Page 7: Maintenance

    2. General description The ecoSMART Supervisor is an electronic device designed to manage a cascade of ecoGEOHP heat pumps. It can work with a minimum of 2 heat pumps and a maximum of 6. To do this you must establish pLAN bus communication with all heat pumps.
  • Page 8: Unpacking

    Supervisor user, installer and technical service manual 3.3. Unpacking To unpack the supervisor, carefully remove the box and check that the unit has not been damaged during transportation. 3.4. Fitting and removing the cover A 4 mm Allen wrench is required to assemble and disassemble the cover. Remove the front cover by loosening the four screws and pulling it.
  • Page 9: Service Areas

    DANGER! Ecoforest recommends installing an automatic external switch for each of the electrical power sources (power supply of the supervisor and power supply of devices controlled by its DO digital outputs).
  • Page 10: General Instructions

    Supervisor user, installer and technical service manual 4.1. General instructions The locations of the main electrical panel components are shown below. Digital outputs Main supply 1/N/PE DOxx 230Vac 50-60 Hz Control Power Supply 230V DO10 DO11 DO12 DO13 L1 L2/N PE Transformer fuse 230Vac 0.5A...
  • Page 11 Supervisor user, installer and technical service manual Figure 4.2. General electrical connection scheme 1. Installation for heating and cooling production with ecoGEO HP3.
  • Page 12 Supervisor user, installer and technical service manual Figure 4.3.General electrical connection scheme 2.Installation for simultaneous production of heating and cooling with ecoGEO HP1...
  • Page 13 Supervisor user, installer and technical service manual  The schemes in figures 4.2 and 4.3 are provided only to indicate the electrical connections. The hydraulic design should be carried out by a specialist. Its use in full or in part, as well as any NOTE reproduction or transfer to third parties, is the responsibility of the installation company.
  • Page 14 Supervisor user, installer and technical service manual  Take special care with the working voltage of each digital input; improper handling could cause poor heat pump operation and/or heat pump component breakdowns. Some digital inputs require NOTE voltage-free signals, while others require 24Vac signals. 24Vac signals are sent from their own terminal block strip.
  • Page 15 Supervisor user, installer and technical service manual Analogue outputs (AOxx) These terminals send analogue 0-10Vdc regulation signals to modulate the control of pumps and/or fans. Moreover, these connectors have a 24Vac power supply terminal for modulating equipment that requires a 24Vac power supply.
  • Page 16: Power Supply

    Supervisor user, installer and technical service manual Figure 4.8. Example of digital output relay power supply connections. Each relay allows independent pole switching; it can thus control the switching on/off of the units, including those powered with a different voltage. The capacity of the relays is 8A/250Vac per pole. If the equipment to be controlled exceeds this capacity, an external relay or contactor must be installed.
  • Page 17: Bus Communication

    Figure 4.11. Example pLAN bus communication cable connection for installations with cascade of heat pumps. Some other Ecoforest devices also communicate with each other via their pLAN ports. In any case, all Ecoforest controllers that connect via pLAN will establish a single pLAN network.
  • Page 18: Control Panel

    Supervisor user, installer and technical service manual 5.1. Control panel The supervisor panel has a screen with 6 buttons, like the one shown in the illustration below. The buttons are used to move through the various user menus and to adjust the parameters.
  • Page 19: Mainscreen

    Supervisor user, installer and technical service manual 5.2. Mainscreen The main screen of the application contains a series of fields with information about heat pump operation. Date and time Status Operation program Operation mode Active components Figure 5.2. Description of the main screen.
  • Page 20: Mode

    Supervisor user, installer and technical service manual 5.4. Mode This field shows the icons that indicate the operating modes that are active. Several operating modes can be viewed simultaneously, depending on the heat pump model and the configuration set up by the technical service.
  • Page 21: Operation Program

    Supervisor user, installer and technical service manual Apart from the icons that define the operating modes, the following icons can also be found in this field. Operation This indicates thermal energy transfer between circuits. If the icon is shown continuously, this indicates normal heat pump operation.
  • Page 22: Heatpump Status

    Supervisor user, installer and technical service manual 5.6. Heatpump status This indicates heat pump availability to service the various heat pump functions. ON status The heat pump is on and available to activate all its functions. ON + EVU status The heat pump is on but the compressor is deactivated by the EVU signal.
  • Page 23: User Menu

    Supervisor user, installer and technical service manual 5.7. User menu In Table 5.1 the sub-menu structure of menu 1. USER is shown. 1. USER menu Sub-menu level 1 Sub-menu level 2 Screen 1.1. On/Off On/Off AUTO settings pLAN address...
  • Page 24 Supervisor user, installer and technical service manual Icono Significado Heat pump ON Heat pump compressor OFF by EVU signal Heat pump OFF by Supervisor Heat pump OFF by BUS Heat pump Off by CONTROL PANEL Heat pump Off by ALARM Heat pump LOCKED by alarm Table 5.2.
  • Page 25 Supervisor user, installer and technical service manual COOLING SETPOINT. Shows the heat pumps connected to supervisor with cooling enabled, also displayed cooling setpoint of each heat pump. The temperatures are the setpoint and the temperature gradient set point in case of installing exchangers in each heat pump.
  • Page 26: Installer Menu

    Supervisor user, installer and technical service manual 5.8. Installer menu In ¡Error! No se encuentra el origen de la referencia. the sub-menu structure of menu 2. INSTALLER is shown. INSTALLER menu Sub-menu Sub-menu Screen level 1 level 2 2.1. Language Change language 2.2.
  • Page 27 Supervisor user, installer and technical service manual BRINE CONFIGURATION. Allows the type of brine system to be selected from among GEOTHERMAL COLLECTOR / AIR UNIT / HYBRID SYSTEM. MENU 2.2.2 Services SERVICES. Allows ENABLED / DISABLED the services activated by the heat pump to in the supervisor.
  • Page 28 Supervisor user, installer and technical service manual BRINE TEMP. ALARM.Allows the value to be set below which the alarm is activated due to low temperatures in the brine circuit. COOLING TEMP.ALARM.Allows the value to be set below which the alarm is activated due to low outlet temperatures in the production circuit.
  • Page 29: Configuration And Commissioning

    HP Supervisor Figure 6.1. Example information screens showing the ecoGEO HP heat pump and ecoSMART Supervisor software version. Check that there is no configuration in the supervisor electronic control. If there are any configuration parameters or if you are not sure, delete the whole configuration using the tool in “installer menu →...
  • Page 30: Control Panel Address Configuration

    Supervisor user, installer and technical service manual In the Figure 6.3.shows cascade configuration for heat pump number 2. Figure 6.3. Cascade configuration example for heat pump number 2. 6.3. Control panel Address configuration The supervisor pLAN communication address is 15. The pLAN communication address of its control panel must therefore be 18. It is not possible to use other addresses for the supervisor and its control panel.
  • Page 31: Plan Communication Cable Connection

    Supervisor user, installer and technical service manual A screen will appear as shown in the figure. Press [←┘] to go to the next screen. In “Trm1” change the control panel address again as shown in the figure. Press [←┘] again and change the control panel privacy “Pr”. Press [←┘] until reaching “No”, which is next to “Ok?”...
  • Page 32: Power Limitation And Protection Configuration

    Supervisor user, installer and technical service manual 6.9. Power limitation and protection configuration To configure the safety protections and operating range limitations of the supervisor access the INSTALLER MENU (press [Prg]+[Esc] and enter the installer password PW1) ->CONFIGURATION -> PROTECTIONS.
  • Page 33: Identifying And Solving Problems

    Supervisor user, installer and technical service manual Commissioning and checking for unusual noises: Check that the temperature readings from different sensors are correct. Start up the whole system (heat pump and Supervisor module) and check that it functions properly in the various operating modes in which it will operate.
  • Page 34: Circuit Diagram

    Supervisor user, installer and technical service manual 8.2. Circuit diagram POWER SUPPLY COIL J10 FBUS1 J11 BMS2 J14 pLAN 24Vac Transformer Max output 63VA pCOOEM+ 24 Vac FBus BMS2 pLAN AI10 AI11 AI12...
  • Page 35: Table Of Electrical Connections

    Supervisor user, installer and technical service manual 8.3. Table of electrical connections DIGITAL OUTPUTS CONNECTIONS DESCRIPTION Connection Controller terminal Type Signal terminal Block I / DO1 pCOOEM+ / J16 / NO1 Activation 250Vac / 8A max Brine pump activation...
  • Page 36 Supervisor user, installer and technical service manual ANALOGUE OUTPUTS CONNECTIONS DESCRIPTION Connection terminal Controller terminal Type Signal Brine pump adjustment / Block II / AO1 pCOOEM+ / J6 / Y1 0-10Vdc Brine simultaneously production valve regulation Production pump regulation /...
  • Page 37: Symbols

    Supervisor user, installer and technical service manual 9. Symbols DHW circuit 3-way valve open/closed Pool 3-way thermostatic valve Heating system 3-way modulating valve 0-10Vdc Cooling system Check valve NTC temperature probe Cut-off valve Relay thermostat Safety valve Differential pressure valve...
  • Page 38 10.1. Manufacturer's warranty ECOFOREST is liable for lack of conformity of the product or its spare parts, in compliance with the current regulations of the country where the product is purchased. The warranty is only valid in the country where the product is purchased.
  • Page 40 ECOFOREST GEOTERMIA, S.L. Parque Empresarial Porto do Molle / Rúa das Pontes, 25 36350 – Nigrán – Pontevedra – Spain Tel.: +34 986 262 184 http://www.ecoforest.es The manufacturer reserves the right to make any necessary changes to the contents of this manual without prior notice.

Table of Contents