Engine Oil Level Check - Westinghouse WGen7500DF User Manual

Dual fuel portable generator; gasoline: 7500 running watts | 9500 peak watts propane: 6750 running watts | 8550 peak watts
Hide thumbs Also See for WGen7500DF:
Table of Contents

Advertisement

MAINTENANCE
DO NOT twist or tear the foam air filter element during
cleaning or drying. Only apply slow but firm squeezing
action.
5. Rinse the air filter element by submerging it in fresh
water and applying a slow squeezing action. Allow the
filter to dry thoroughly.
Do not pollute. Follow the guidelines of the EPA or other
governmental agencies for proper disposal of hazardous
materials. Consult local authorities or reclamation facility.
6. Dip the foam air filter in clean engine oil then squeeze
out all excess oil. The engine will smoke when started if
too much oil is left in the filter.
7. Install the foam air filter in the housing, then the coarse
air filter. Install the air cleaner cover and secure with the
cover clamps.
24 | Westinghouse Outdoor Power Equipment, LLC
NOTICE
NOTICE

ENGINE OIL LEVEL CHECK

Avoid skin contact with engine oil. Wear protective
clothing and equipment. Wash all exposed skin with
soap and water.
Always use the specified engine oil. Failure to use the
specified engine oil can cause accelerated wear and/or
shorten the life of the engine.
When using the generator under extreme, dirty, dusty
conditions or in extremely hot weather, change the oil
more frequently.
Ambient air temperature will affect engine oil performance.
Change the type of engine oil used based on weather
conditions.
Check the engine oil level before each use or every 8
hours of operation.
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. With a damp rag, clean around the oil dipstick.
3. Remove the oil dipstick and wipe the dipstick clean.
NOTICE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wgen7500

Table of Contents