2 . Open the cover panel.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.
(Refer to the picture below)
• E ach wire is labeled with the corresponding terminal number.
5 . Pass the other end of the cable through the 65 mm hole in the wall.
6 . Close the connector cover by tightening the screw carefully.
7 . Close the cover panel.
8 . Remove the terminal board cover on the side of the outdoor unit.
9. Connect the cables to the terminals as seen in the picture.
• E ach wire is labeled with the corresponding terminal number.
Indoor unit
Outdoor unit
Outdoor unit
• Also circular terminal must be matched with screw size in terminal block.
• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.
• P lease ensure that Power & Communication cables are separated, they must not be in the same cable.
10. Connect the grounding conductor to the grounding terminals.
11. Close the terminal board cover by tightening the screw carefully.
• I n Russia and Europe, consult with the supply authority to determine the supply system impedance before
installation.
• C onnect the wires fi rmly so that wires can not be pulled out easily.
(If they are loose, it could cause burn-out of the wires.)
• C onnect the wires according to color codes, referring to the wiring diagram.
• T he power cable and the interconnection cable should be selected according to the specifi cation in page 32.
Maldives FJM Brazil_IB&IM_DB68-05639A-00_EN.indd 33
Indoor unit
1(L) 2(N) F1
1(L) 2(N) F1
Power cable to
indoor units
1(L) 2(N) 1(L) 2(N)
Outdoor unit
English-33
F2
F2
Main Power
Supply cable
F1 F2 F1 F2
L
N
2
1
A
2015/8/15 10:45:02