Chapter 1 Overview Chapter 1 Overview This chapter mainly introduces the naming rules, main components and technical parameters of the Liebert.CRV+ condenser (condenser for short). 1.1 Naming Rules Liebert.CRV+ condenser naming rules are described in Figure 1-1. L SF 12 -R3 R410A System Applicable to 12kW Unit 220V/1ph/50Hz Chopper speed-governing...
Chapter 1 Overview Table 1-1 Mechanical parameters of condenser Condenser model Dimensions(W X D X H, mm) Net weight (kg) LSF12-R3 787×352×1240 1.3.2 Dimensions of Mounting Base The dimensions of mounting holes of the base of the condenser are shown in Figure 1-3. Figure 1-3 Dimensions of mounting holes of the base of the condenser (top view, unit: mm) 1.3.3 Parameters Of Operating Environment The operation environment parameters of the condenser meet GB/T4798.3 and GB/T19413.
Chapter 2 Mechanical Installation Chapter 2 Mechanical Installation This chapter introduces the moving, unpacking, inspection, installation notes, space requirements and installation procedures. 2.1 Moving, Unpacking And Inspection Moving It is recommended to use mechanical transport equipment such as forklift or crane when unloading and transferring the condenser closest to the installation site.
Chapter 2 Mechanical Installation 7. Prepare a base that can withstand the weight of the outdoor unit (see table 1-1 for the specific weight). The height of the base should be at least 50mm above the ground and should be higher than the base of outdoor unit by 50mm, as shown in Figure 2-2.
Page 9
Chapter 2 Mechanical Installation Connecting cables Note 1. The protected tube or shielded line is required for the outdoor part of the connection cable between the indoor unit and the condenser. The ground cable should be connected to the ground nearby, and the length cannot exceed 3m. 2.
Chapter 3 Maintenance And Troubleshooting Chapter 3 Maintenance And Troubleshooting This chapter introduces the maintenance and troubleshooting of the condenser. Users should check the condenser regularly and solve the problems in time. Note 1. The maintenance of the condenser must be done by technicians. 2.
Means the content of the hazardous substances in at least one of the average quality materials of the part is outside the limits specified in SJ/T11363-2006 Emerson Network Power Co., Ltd. has been committed to the design and manufacturing of environment-friendly products. It will reduce and eventually eliminate the harzardous substances in the products through unremitting efforts in research. However,...