Summary of Contents for Fisher Scientific Isotemp 153

  • Page 1 Isotemp ® Explosion-Proof Refrigerators and Freezers Refrigerator Model 153, 153HK Freezer Model 150, 150HK 104354 • 9/15/06...
  • Page 2: Table Of Contents

    Table of Contents Safety Information ..............................3 Alert Signals..............................3 Unpacking ................................4 Visible Loss or Damage..........................4 Concealed Loss or Damage ........................4 Installation ................................5 Selecting a Location ............................5 Leveling The Unit ............................5 Shelves ................................5 Electrical Connection ............................5 Operation ................................6 Initial Startup ..............................6 Temperature Control ............................6 Condensate Disposal............................6 Material Compatibility ..........................7 Troubleshooting ..............................8...
  • Page 3: Safety Information

    Safety Information Your satisfaction and safety are important to Fisher Alert Signals Scientific and a complete understanding of this unit is necessary to attain these objectives. Warning As the ultimate user of this apparatus, it is your responsi- Warnings alert you to a possibility of bility to understand its proper function and operational personal injury.
  • Page 4: Unpacking

    Unpacking Save all packing material if apparatus is received dam- aged. This merchandise was carefully packed and thor- oughly inspected before leaving our factory. Responsibility for its safe delivery was assumed by the carrier upon acceptance of the shipment; therefore, claims for loss or damage sustained in transit must be made upon the carrier by the recipient as follows: Visible Loss or Damage...
  • Page 5: Installation

    Installation Selecting a Location Choose a location for the refrigerator that will provide at least three inches of clearance between the cabinet and any adjacent vertical surface at the sides and four inches at the rear. Four inches of clearance is required above the top.
  • Page 6: Operation

    Operation Initial Startup This unit is not equipped with a power switch. Turn the Warning applicable facility circuit breaker off during installation. If the unit is tilted in excess of 30 Simply turn power on the facility’s circuit that supplies the degrees, do not apply electrical power unit.
  • Page 7: Material Compatibility

    PERATION Material Compatibility The interior cabinet of this unit is constructed of epoxy- coated steel. Care must be exercised when determining which chemicals may be stored in the refrigerator and freezer sections and which type of storage materials should be employed. ABS Plastic deteriorates when exposed to, but not limited to, the following: Aliphatic Hydrocarbons;...
  • Page 8: Troubleshooting

    Troubleshooting This table is intended to assist in resolving user-correctable Refrigerator problems by relating symptoms to their likely causes. If service beyond the scope of this table is required, contact your nearest Fisher Scientific Service Office. Symptom Probable Cause Action...
  • Page 9: Maintenance

    Maintenance Cabinet Cleaning Caution The cabinet interior should be cleaned frequently. Any When servicing the unit, disconnect spilled liquid should be wiped off immediately since stains from the electrical power source. resulting from some spills could be permanent if not quickly removed.
  • Page 10: Performance Characteristics

    Performance Characteristics and Replacement Parts Performance Characteristics Temperature Ranges 150: - 20°C to -12°C (- 4°F to +10°F) 153: 2°C to 10°C ( 36°F to 50°F) Temperature Stability at 4°C: +4°C at -20°C : +4°C Electrical Requirements 13-986-150 115 Volts ±10%, 60 Hz, 5.0 Amps 13-986-150HK 220 Volts ±10%, 50 Hz, 5.0 Amps 13-986-153 115 Volts ±10%, 60 Hz, 5.0 Amps...
  • Page 12: Warranty

    Warranty Laboratory instruments and equipment manufactured by Fisher Scientific Company L.L.C. – Laboratory Equipment Division (hereinafter called “the Company”) are warranted only as stated below. Subject to the exceptions and upon the conditions specified below, the Company agrees, at its election, to...