Technical Specifications; Reach; Troubleshooting - Stihl RLE 540 Instruction Manual

Hide thumbs Also See for RLE 540:
Table of Contents

Advertisement

Available languages

Available languages

– Measured sound power level: 86 dB(A)
– Guaranteed sound power level:
89 dB(A)
The technical documents are stored in the
Product Approval department at STIHL
Tirol GmbH.
The year of manufacture and machine
number are indicated on the scarifier.
Langkampfen, 27.01.2021
STIHL Tirol GmbH
FN 46276 d, Innsbruck Regional Court
p.p.
Matthias Fleischer, Head of Research and
Development Division
p.p.
Sven Zimmermann, Head of Quality
Division
_________________________________
Importer for Great Britain
ANDREAS STIHL Ltd.
Stihl House
Stanhope Road
0478 670 9906 B - EN
CAMBERLEY
SURREY GU15 3YT
Great Britain

18. Technical specifications

Type
RLE 540.0
Serial number
6290
Motor, design
Electric motor
Voltage
230 V~
Power input
1600 W
(EU) 2019/1781
§2(2) (j)
Frequency
50 Hz
Fuse
10 A
Protection class
II
Type of protection
IPX 4
Scarifying device
14 fixed vertical
blades
Scarifying blade
drive
Permanent
Motor output speed
2840 rpm
Working width
38 cm
Working depth
6 levels, adjust-
ment range
25 mm
Wheel diameter
(front)
180 mm
Wheel diameter
(rear)
180 mm
Length
126 cm
Width
54 cm
Height
111 cm
Weight
28 kg
Sound emissions:
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
89 dB(A)
WAd
In accordance with Directive 2006/42/EC:
Type
RLE 540.0
Sound pressure level
at workplace L
72 dB(A)
pA
Uncertainty K
2 dB(A)
pA
Hand-arm vibrations:
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
1,95 m/sec
hw
Uncertainty K
0,98 m/sec
hw
Measurement in accordance with
EN 20643

18.1 REACH

REACH is an EC Directive for the
registration, evaluation, authorisation and
restriction of chemicals.
Information on compliance with the
REACH Directive (EC) No. 1907/2006 is
available from www.stihl.com/reach.

19. Troubleshooting

If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.
Fault:
Motor not starting
Possible cause:
– No mains voltage
– Scarifying unit not in transport position
– ON button not pressed
– Blade shaft blocked
– Electric cable/plug and plug connector
or switch defective
2
2
41