Honeywell PS1202C Manual page 13

Replacement power supply kits for electronic air cleaners
Table of Contents

Advertisement

Available languages

Available languages

PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS
PERFORMANCE
SWITCH
ON
(YELLOW)
WASH
(YELLOW)
CHECK
(RED)
LAMP
4
A5
OFF
A6
LO
MED
HI
ON-OFF/3-SPEED
FAN SWITCH
1
BROWN
BROWN
1
BLUE
BLUE
2
GROUND
3
Fig. 17. Retrofitted/original equipment F57 220-240V model electrical schematic.
BLACK COLLECTOR
RED IONIZER
POWER SUPPLY
4
6
ORANGE
BLACK
BROWN
A3
A4
B3
B1
B4
B2
C3
C1
C4
C2
D3
D1
VIOLET
D2
D4
3
RED
4
BLACK
WHITE
WHITE
WHITE
RED
1
TERMINAL BOARD FOR POWER SUPPLY CONNECTIONS.
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
BLUE
2
INTERLOCK SAFETY SWITCH.
3
PROVIDES ON-OFF INDICATION.
4
LEFT CELL AND CONTACT BOARD ON
TWO-CELL AIR CLEANER ONLY.
FAN
5
REMOVE J8 SHORTING BAR. CONNECT BLACK LEADS
MOTOR
FROM PERFORMANCE SWITCH TO J8.
6
CABLE WITH FLYING LEDS IS CONNECTED TO J2 ON
THE RPI DRIVER.
13
TEST
BUTTON
CONTACT
BOARD
M33501A
69-1137EF—03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps2402c

Table of Contents