Honeywell PS1202C Manual page 10

Replacement power supply kits for electronic air cleaners
Table of Contents

Advertisement

Available languages

Available languages

PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS
RPID BOARD
J2
1
2
3
4
5
6
J1
P1
1 2 3 4 5 6 7
L1
(HOT)
1
L2
GROUND
PERFORMANCE
SWITCH
ON
(YELLOW)
WASH
(YELLOW)
CHECK
(RED)
ON-OFF/3-SPEED FAN SWITCH
PUSH BUTTONS
HI
MED
LO
OFF
BLACK
L1
(HOT)
1
L2
GROUND
Fig. 14. Retrofitted/original equipment F57 120 Vac model electrical schematic.
69-1137EF—03
PERFORMANCE
SWITCH
BLACK
BLACK
ON
(YELLOW)
WASH
(YELLOW)
CHECK
(RED)
ON-OFF/3-SPEED FAN SWITCH
WIRING TERMINALS
PUSH BUTTONS
HI
ON
MED
HI
LO
MED
OFF
LO
BLACK
ORANGE
3
Fig. 13. Recent F57 120V model electrical schematic.
4
5
WIRING TERMINALS
ON
HI
MED
LO
ORANGE
3
BLACK COLLECTOR
RED IONIZER
POWER SUPPLY
BROWN
VIOLET
BLUE
RED
FAN
MOTOR
WHITE
BLACK COLLECTOR
RED IONIZER
POWER SUPPLY
2
BROWN
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
VIOLET
2
LEFT CELL AND CONTACT BOARD ON
BLUE
TWO-CELL AIR CLEANER ONLY.
RED
3
INTERLOCK SAFETY SWITCH.
4
REMOVE J8 SHORTING BAR. CONNECT BLACK
FAN
LEADS FROM PERFORMANCE SWITCH TO J8.
MOTOR
5
CABLE WITH WIRES TO W8600 TERMINAL STRIP
IS CONNECTED TO J2 ON THE RPI DRIVER.
WHITE
10
TEST
BUTTON
RED
2
BLACK
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
2 LEFT CELL AND CONTACT BOARD ON
TWO-CELL AIR CLEANER ONLY.
3 INTERLOCK SAFETY SWITCH.
TEST
BUTTON
RED
BLACK
CONTACT
BOARD
M33496A
CONTACT
BOARD
M33497A