SECTION 13
MOTOR LUBRICATION
Rotating machinery can cause injury or death. Open main disconnect, lockout
and tagout power supply to compressor package before working on the electric
motor.
Motor Lubrication - Long time satisfactory operation of an electric motor depends in large measure on
proper lubrication of the bearings. The following charts show recommended grease qualities and re-
greasing intervals for ball bearing motors. For additional information refer to the motor manufacturer's
instructions. The following procedure should be used in re-greasing:
1. Disconnect, lockout and tagout power supply to the compressor package.
2. Wipe lubrication fitting clean and add grease with a hand-operated grease gun.
3. Wipe off only excess grease expelled by the automatic grease relief fitting supplied.
4. Restart the unit.
Main motors and aftercooler fan motor have automatic grease relief fittings.
Main Motor Grease Specifications:
MANUFACTURER
KLUBER
Type of
Service
Standard
Severe
Humid, dirty, high ambient sites
TRADE NAME
KLUBERQUIET BHQ 72-72
ELECTRIC MOTOR REGREASING INTERVAL
Typical
Continuous Operation
13-17-605 Page 74
GD Part No.
28H311
(400 Gram Cartridge)
Rating
Lubrication Interval
55-90 kW
55-90 kW
8000 hrs
4000 hrs