SECTION 13
MOTOR LUBRICATION
Rotating machinery can cause injury or death. Open main disconnect, lockout and
tagout power supply to compressor package before working on the electric motor.
Motor Lubrication - Long time satisfactory operation of an electric motor depends in large measure on
proper lubrication of the bearings. The following charts show recommended grease qualities and re-
greasing intervals for ball bearing motors. For additional information refer to the motor manufacturer's
instructions. The following procedure should be used in re-greasing:
1. Disconnect, lockout and tagout power supply to the compressor package.
2. Locate the automatic grease relief fittings (one at each motor bottom end) and make sure that their
spring loaded covers are operational.
3. Locate the grease fittings provided at each end of the motor top end – be aware the one or both may
be relocated away from the motor for easier access. Wipe each grease fitting clean and add grease
with a hand - operated gun until excess grease starts draining from the companion grease relief
fitting.
4. Wipe off only excess grease expelled by the automatic grease relief fittings.
5. Re-start the unit.
Main Motor Grease Specifications:
MANUFACTURER
KLUBER
Type of
Service
Continuous Operation
ALL
Humid, dirty, high ambient sites
TRADE NAME
KLUBER QUIET BQ 72-72
ELECTRIC MOTOR REGREASING INTERVAL
Typical
13-18-612 Page 75
GD Part No.
28H311 (400 Gram Cartridge)
28H312 (1Kg can)
28H313 (25 Kg pail)
Rating
Lubrication Interval
80-110 kW
3000 hrs
13-1