The Target Pressure is the second item in the Operation Adjustment sub-menu so press the
Down
button to navigate to the Target Pressure setting.
OPERATION ADJUSTMENT
TARGET PRESSURE
100 PSI
(SELECT PARAMETER)
To change the Target Pressure, press the Enter
OPERATION ADJUSTMENT
TARGET PRESSURE
100 PSI
(EDIT PARAMETER
A flashing cursor will appear covering the least significant digit in the Target Pressure value, use
the Plus
and Minus
buttons to move the cursor to other digits in the Target Pressure value. When the desired Target
Pressure value is displayed, press the Enter
Stop/Reset
button will abort the change and restore the previous value.
In order to save the changes made to parameters, press the Stop/Reset button to go back to the
heading of the current menu and then press the Stop/Reset button again. If parameter changes
have been made, the following screen will appear.
STORE MODIFIED
PARAMETERS?
STOP = NO
ENTER = YES
To permanently save the changes that were made, press the Enter
Stop/Reset button is pressed, the parameter changes will be lost the next time the compressor
power is turned off.
)
buttons to change its value. Use the Right
button to save the new value. Pressing the
13-17-605
Page 24
button to edit the value.
and Left
button. If the